The Philips Adult Hard Shell SpO2 Sensor 3.0m (Nellcor OxiMax Technology) is a reusable finger-clip pulse oximetry probe that plugs into Philips IntelliVue, SureSigns and M3000-series monitors fitted with a Nellcor OxiMax SpO2 module.
It measures oxygen saturation (SpO2) and pulse rate on adult patients, is built to the Unimed U410-91P reference specification, and ships brand new with a 3.0 metre cable for flexible bedside positioning.
Key Benefits of This Philips OxiMax SpO2 Sensor
- Reusable hard shell design a rigid, spring-loaded finger clip that can be cleaned and reused across many patients, lowering cost per measurement compared with disposable adhesive probes.
- Nellcor OxiMax signal technology made for Philips monitors and modules configured with the Nellcor OxiMax SpO2 parameter.
- Long 3.0 m (approx. 9.8 ft) cable reaches from monitor to patient without an extension cable in most ward, ICU and theatre layouts.
- 8-pin Philips-style D-shaped connector direct plug-in to the monitor or MMS SpO2 port, no adapter needed on OxiMax-equipped units.
- Patient-friendly clip soft inner pads grip the finger evenly for stable readings during spot checks and continuous monitoring.
- Quality certified
Features at a Glance
Adult Finger Clip Sensor Head
The grey hard shell housing holds the emitter and detector in fixed alignment over the fingertip, helping to reduce motion artefact and ambient light interference. The spring hinge suits a wide range of adult finger sizes.
Durable 3.0 m Patient Cable
A flexible blue cable resists kinking and routine cleaning, and the strain relief at both ends protects the internal conductors during daily handling.
Direct Philips Monitor Connection
The single-piece design connects straight to Philips systems with a Nellcor OxiMax SpO2 input, so there is no separate interface cable to manage.
Philips OxiMax SpO2 Sensor Specifications
| Specification | Detail |
|---|---|
| Product | Adult Hard Shell (Finger Clip) SpO2 Sensor |
| Brand Fit | Philips |
| SpO2 Technology | Nellcor OxiMax |
| Patient Size | Adult |
| Sensor Type | Hard shell finger clip |
| Connector | 8-pin, Philips-style D-shaped |
| Cable Length | 3.0 m (approx. 9.8 ft) |
| Lifecycle | Reusable |
| Reference Part Number | Unimed U410-91P |
| Packaging | 1 pc per bag |
| Condition | New |
Cross-Reference Part Number
| Brand | Reference Number |
|---|---|
| Unimed | U410-91P |
Works With These Philips Monitors (Nellcor OxiMax Configuration)
- IntelliVue bedside monitors: MP2, MP5SC, MP5T, MP20, MP20 Junior, MP30, MP40, MP50, MP60, MP70, MP80, MP90 (Nellcor OxiMax)
- IntelliVue MX series: MX100, MX400, MX430, MX450, MX500, MX550, MX600, MX700, MX800 (Nellcor OxiMax)
- IntelliVue transport & other: X2, X3, XG50 (Nellcor OxiMax)
- Model numbers: 865240, 865241, 865242, 866060, 866061, 866062, 866064, 866066 (Nellcor OxiMax); M8001A, M8002A, M8003A, M8004A, M8005A, M8007A, M8008A, M8010A (Nellcor OxiMax); M8102A, M8105A, M8105AS, M8105AT
- Measurement modules & M-series: M3000A, M3001A (A02/A03/A04 incl. C06, C12, C18 options), M3002A (incl. MMS X2, Nellcor-OxiMax), M1020A, M1020B, M3500B, M4735A
- Other Philips systems: Heartstream XL, SureSigns VS2, VS3, VS4, VM4
Tip: Philips monitors ship with different SpO2 technologies (Philips FAST, Masimo SET or Nellcor OxiMax). Check that your monitor or module is configured for Nellcor OxiMax before ordering. For FAST-SpO2 units, see the Philips FAST sensors linked below.
Typical Use Cases
- Continuous SpO2 and pulse rate monitoring in ICU, CCU and high-dependency units
- Operating theatres, anaesthesia and post-anaesthesia recovery (PACU)
- Emergency department triage and resuscitation bays
- General ward spot checks and vital signs rounds
- Patient transport using IntelliVue X2/X3 or MP2 monitors
- Biomedical engineering spares and replacement stock for Philips fleets
Care and Cleaning
- Disconnect the sensor from the monitor before cleaning.
- Wipe the clip pads and cable with a soft cloth dampened with 70% isopropyl alcohol or a mild hospital-grade disinfectant.
- Do not immerse, autoclave or gas sterilise the sensor.
- Allow to dry completely before reuse and inspect the cable and clip for damage.
- Reposition the sensor site at least every 4 hours during continuous monitoring.
Frequently Asked Questions
Which Philips monitors does this adult hard shell SpO2 sensor work with?
It works with Philips IntelliVue MP and MX series monitors, X2/X3 modules, M3001A/M3002A measurement servers, SureSigns VS2/VS3/VS4/VM4 and other listed Philips systems, provided they are configured with Nellcor OxiMax SpO2 technology.
Will this sensor work on a Philips monitor with FAST-SpO2?
This sensor is designed for Philips systems running Nellcor OxiMax SpO2. Monitors using native Philips FAST-SpO2 normally require a FAST sensor such as the M1191AL or M1196A styles.
What is the cable length?
The integrated cable is 3.0 metres (about 9.8 feet), long enough for most bedside setups without an extension cable.
Is the sensor reusable?
Yes. It is a reusable hard shell finger clip sensor that can be cleaned and disinfected between patients according to your facility protocol.
What patient size is it for?
It is sized for adult patients, applied to the index, middle or ring finger.
What part number does it cross-reference?
It is built to the Unimed U410-91P reference specification.
Is this sensor new?
Yes. Every unit is brand new and supplied individually bagged.