The Philips M1192AL pediatric hard shell SpO2 sensor is a new, reusable finger-clip pulse oximetry probe built to the Philips FAST reference specifications for continuous pulse oximetry monitoring. It uses an 8-pin Philips/HP FAST connector at the end of a 3.0 metre cable and is designed as a direct-fit reference match for pediatric patients on Philips IntelliVue, SureSigns, and Viridia patient monitoring platforms.
Key Features and Benefits
- Reusable, pediatric hard-shell design — rigid clip housing sized for a child’s finger, holding the sensor securely in place during continuous monitoring.
- 3.0m FAST cable — extended reach for bedside or cot-side monitors positioned away from the patient.
- 8-pin Philips FAST connector — built to the Philips M1192AL reference specifications for a plug-and-play fit.
- New condition — ships in original protective packaging, not refurbished.
- 12-month warranty — backed against manufacturing defects.
- Cost-effective fleet spare — a lower-cost option for hospitals and clinics maintaining multiple pediatric SpO2 sensor cables.
Technical Specifications
| Specification | Detail |
|---|---|
| Reference Model | Philips M1192AL |
| Cross-Reference | Unimed U110-91 |
| Cable Length | 3.0m |
| Patient Size | Pediatric |
| Sensor Type | Hard Shell (Finger Clip) |
| SpO2 Technology | Philips FAST |
| Connector | 8-Pin Philips/HP FAST |
| Lifecycle | Reusable |
| Condition | New |
| Warranty | 12 Months |
Which Patient Monitors This SpO2 Sensor Works With
supported Monitor Platforms
- Philips IntelliVue MP20, MP30, MP40, MP50, MP60, MP70, MP80, and MP90 series monitors, plus IntelliVue MX400–MX800 series
- Philips SureSigns VM1, VM4, VM6, VM8, VS2, VS3, and VS4 monitors
- Philips/Agilent/HP Viridia 24C and M3/M4-series monitors, and HeartStart XL/MRx/4000 defibrillator-monitors
- Goldway G40 and Mindray V12 patient monitors
- Solaris NT2A and NT2C patient monitors
Common Use Cases
- Continuous pediatric SpO2 monitoring in hospital wards, PICUs, and step-down units
- Replacement for a worn, cracked, or intermittently reading OEM sensor cable
- Stocking spare for biomedical and clinical engineering departments managing multiple Philips monitors
Frequently Asked Questions
What is the difference between this and the adult Philips FAST hard shell sensor?
Both use the same 8-pin FAST connector and hard-shell clip design. This M1192AL reference is sized and shaped for pediatric patients, while the adult M1196AL reference uses a larger clip for adult fingers.
Which monitors can I use this sensor with?
It works with Philips IntelliVue and SureSigns monitors, HP/Agilent Viridia monitors, and other platforms listed above that use the 8-pin Philips FAST SpO2 connector.
What patient size is this sensor designed for?
Pediatric. The hard-shell clip is sized for a child’s finger rather than an adult or neonate.
What is the condition and warranty?
This sensor is new (not refurbished) and is covered by a 12-month warranty against manufacturing defects.
Related Pediatric and Philips SpO2 Sensors
Looking for a different model, patient size, or cable length? See our Philips 8-Pin Reusable SpO2 Sensor family (M1196A, M1191BL, M1193A, M1192A, M1194A), Philips M1191BL Adult Soft Tip SpO2 Sensor, 3.0m, Philips M1194B Adult Ear Clip SpO2 Sensor, 1.0m, Pediatric Hard Shell SpO2 Sensor, Nellcor D-YSPD (Non-Oximax), and Masimo 4050 RD Set DCI Short SpO2 Adult Clip for other pediatric and adult SpO2 sensor options.
















Reviews
There are no reviews yet.