The Masimo 2320 LNCS Neo-3 adult/neonate SpO2 sensor is a single-patient-use, non-woven adhesive pulse oximetry sensor built to the Masimo 2320 (LNCS Neo-3) reference specifications.
It uses Masimo LNCS technology, has a 0.9m (3 ft) cable, is packed 20 sensors per box, and is supplied brand new for continuous oxygen saturation (SpO2) and pulse rate monitoring on neonatal and adult patients.
Why Choose This LNCS Neo-3 Disposable SpO2 Sensor
- Dual patient size: One sensor design covers both neonate and adult applications, reducing the number of SKUs your ward needs to stock.
- Soft non-woven adhesive: Gentle, breathable tape wraps securely around the foot, hand or finger for stable readings with minimal skin irritation.
- Single-patient use: A fresh sensor for every patient supports infection-control protocols and removes reprocessing time.
- Masimo LNCS technology: Built to work with Masimo LNCS patient cables and LNCS-enabled monitors, defibrillators and pulse oximeters.
- Cost-effective bulk pack: 20 sensors per box for NICU, theatre, ED and ward stock.
Key Features of the Adult/Neonate Adhesive Pulse Oximeter Sensor
- Built to the Masimo 2320 LNCS Neo-3 reference specifications
- 0.9m (3 ft) sensor cable with LNCS-style connector
- Non-woven adhesive wrap with printed LED/detector alignment marks
- Lightweight, low-profile design suited to delicate neonatal skin
- Condition: New
Masimo 2320 SpO2 Sensor Specifications
| Specification | Detail |
|---|---|
| Reference Model | Masimo 2320 (LNCS Neo-3) |
| SpO2 Technology | Masimo LNCS |
| Patient Size | Adult / Neonate |
| Sensor Type | Non-woven adhesive |
| Lifecycle | Disposable (single-patient use) |
| Cable Length | 0.9m (approx. 3 ft) |
| Pack Quantity | 20 pcs per box |
| Condition | New |
Cross-Reference Part Numbers
This sensor matches the following OEM and industry reference numbers:
| Brand | Reference Number |
|---|---|
| Masimo | 2320 (LNCS Neo-3), 2329 (LNCS Neo), 2321, 2330, 2331, 2604, 2605, 1776, 1862, 1901, LNCS NeoPt, LNCS Neo-L |
| GE Healthcare | 2066336-001, 2051069-001, 2068423-088 |
| Marquette | 2027256-001 |
| Datascope | 0600-00-0125, 0600-00-0157, 520N-30-64401 |
| Draeger | MP00792 |
| Philips | 989803148271 |
| Physio-Control | 11171-000028 |
| Zoll | 8000-0323 |
| Unimed | U543-49R |
Works With These Monitors and Devices
Masimo & Patient Monitors
- Masimo: Pronto 7, Rad-5, Rad-57, Rad-87, Rad-8, Radical-7
- GE Healthcare: Carescape B650, B850, V100; B40, B125, B125M; Dash Series; Dinamap ProCare, Pro 300V2, ProSeries V2, V300; SOLAR Series; TRAM 450SL
- Marquette: Dash 2000/2500/3000/4000/5000, Eagle, Solar 7000/8000/8000M, TRAM 451 & TRAM Modular, PDM Module
- Datascope / Mindray: Accutorr Plus, Accutorr 3/7, Passport 2/2LT/XG/8/12/V, DPM4/6/7, Spectrum, Trio, Duo, PM 6000–9000, BeneView T1/T5/T8, BeneHeart D6
- Philips: IntelliVue MX700 (Masimo Rainbow)
- Draeger: Infinity M540, Narkomed 6400
- Datex Ohmeda: S/5, Giraffe Infant Warmer
Defibrillators & Vital Signs Monitors
- Physio-Control: Lifepak 11, 12, 15, 20, 20E
- Zoll: E Series, M Series, R Series, X Series
- Welch Allyn: Propaq CS, Propaq LT, Spot Vital Signs LXi, Spot Vital Signs 42MTB-E1
- Others: Bitmos SAT 800/801/805/816, Comen K12 Pro, Invivo Escort II, Mennen Horizon XVu, Respironics Alice 5
Always confirm your monitor runs Masimo LNCS SpO2 and uses a matching LNCS patient cable before ordering.
Clinical Use Cases
- NICU and special care nursery continuous SpO2 monitoring
- Operating theatre and post-anaesthesia (PACU) monitoring
- Emergency department and ambulance/EMS transport with Lifepak or Zoll defibrillators
- Adult ICU patients requiring single-patient-use sensors for infection control
- Sleep studies and respiratory care
How to Apply the Neonate/Adult Adhesive SpO2 Sensor
- Choose the site: foot or hand for neonates, finger for adults.
- Remove the backing and align the emitter and detector marks directly opposite each other.
- Wrap the adhesive snugly without over-tightening, then connect to the LNCS patient cable.
- Check the site regularly and replace the sensor when adhesion weakens or per your facility protocol.
Frequently Asked Questions
What is the Masimo 2320 LNCS Neo-3 sensor used for?
It is a disposable adhesive pulse oximetry sensor for measuring oxygen saturation (SpO2) and pulse rate on neonatal and adult patients connected to Masimo LNCS-enabled monitors.
How many sensors come in one box?
Each box contains 20 single-patient-use sensors.
What is the cable length?
The sensor cable is 0.9m (approximately 3 ft).
Is this sensor reusable?
No. It is designed for single-patient use and should be discarded after use on one patient.
Do I need a patient cable?
Most LNCS monitors connect this sensor through a Masimo LNCS patient/extension cable. Check your monitor’s SpO2 port before ordering.
What is the difference between LNCS Neo-3 and LNCS Neo?
Both are adult/neonate adhesive sensors. The Neo-3 (2320) has a 0.9m (3 ft) cable, while the LNCS Neo (2329) OEM version uses a shorter 18-inch cable.
Is the product new?
Related SpO2 Sensors
Neonate Wrap SpO2 Sensor Masimo LNCS | Masimo 2258 LNCS Multi-Y SpO2 Sensor | Masimo 1864 Pediatric Hard Shell SpO2 Sensor | Nellcor MAX-N Adult/Neonate Adhesive SpO2 Sensor | Nihon Kohden Adult Non-Woven Adhesive SpO2 Sensor
















Reviews
There are no reviews yet.