The Masimo 2606 SpO2 sensor reference is a disposable, non-adhesive foam wrap pulse oximetry sensor for adult and neonatal patients. Built to the Masimo 2606 reference specifications, it uses Masimo LNCS technology, has a 0.9m cable and is supplied new in a box of 20 single-patient-use sensors. It measures blood oxygen saturation (SpO2) and pulse rate on patient monitors and pulse oximeters equipped with Masimo SET and an LNCS sensor connection.
Key Benefits of the Masimo LNCS Non-Adhesive Foam SpO2 Sensor
- Gentle on fragile skin: The soft foam wrap holds the sensor in place without adhesive touching the patient, which suits neonates and adults with delicate or compromised skin.
- Two patient groups, one sensor: The Adult/Neonate design wraps around an adult finger or a neonate foot or hand.
- Infection control: Disposable, single-patient-use construction helps lower cross-contamination risk between patients.
- Easy to reposition: The foam strap can be opened and re-wrapped during site checks on the same patient.
- Ward-ready quantity: 20 sensors per box for NICU, theatre, recovery and general ward stock.
Features
- Non-adhesive foam wrap sensor style
- Masimo LNCS SpO2 technology and LNCS connector
- 0.9m (approx. 3 ft) sensor cable
- Patient size: Adult/Neonate
- Disposable, single-patient use
Technical Specifications
| Specification | Detail |
|---|---|
| Product | Adult/Neonate Non-Adhesive Foam SpO2 Sensor |
| Reference Part Number | Masimo 2606 |
| SpO2 Technology | Masimo LNCS |
| Sensor Type | Non-adhesive foam wrap |
| Patient Size | Adult/Neonate |
| Cable Length | 0.9m (approx. 3 ft) |
| Lifecycle | Disposable, single-patient use |
| Pack Size | 20 pcs per box |
| Condition | New |
| SKU | MAS-SPO2-2606-LNCS-ADLNEO-FOAM-0.9M |
Part Number Cross-Reference
| Brand | Reference Number |
|---|---|
| Masimo | 2606 |
| Unimed | N543-49R |
Works With These Monitors
This foam SpO2 sensor works with monitors and pulse oximeters that use Masimo SET with an LNCS sensor connection, including:
- Masimo: Pronto 7, Rad 5, Rad 57, Rad 87, Rad-8, Radical-7
- GE Healthcare: B125, B125M, B40, Carescape B650, Carescape B850, Carescape V100 with Masimo technology, Dash Series, Dinamap ProCare, SOLAR Series, TRAM 450SL
- Marquette: Dash 2000, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Eagle, Solar 7000, Solar 8000, Solar 8000M, Tram 451, PDM Module
- Mindray: Accutorr V, BeneHeart D6, BeneView T1, BeneView T5, BeneView T8, IPM Series, Passport 12, Passport 2, Passport 8, Passport V, PM 6000, PM 7000, PM 8000, PM 9000, Spectrum, Spectrum OR, TM80, Trio
- Datascope: Accutorr 3, Accutorr 7, Accutorr Plus, DPM4, DPM6, DPM7, Passport 2LT, Passport XG, PM 6800
- Datex Ohmeda: Giraffe Infant Warmer, S/5
- Draeger: Infinity M540, Narkomed 6400
- Philips: IntelliVue MX700 with Masimo Rainbow
- Physio-Control: Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E
- Welch Allyn: 1500, Propaq CS, Propaq LT, Spot Vital Signs, Spot Vital Signs LXi
- Zoll: E Series, M Series, R Series, X Series
- Others: Bitmos sat 800/801/805/816, Comen K12 Pro, Invivo Escort II, Mennen Medical Horizon XVu, Respironics Alice 5
Always confirm that your monitor is fitted with Masimo SET and accepts an LNCS sensor or LNCS patient cable before ordering.
Use Cases
- Neonatal intensive care and special care nurseries where adhesive must be kept off the skin
- Adult patients with fragile, burned or sensitive skin
- Operating theatres, recovery and intensive care spot or continuous monitoring
- Emergency departments and patient transport
- Sleep studies and general ward observation
Application and Care
- Select a well-perfused site: an adult finger, or the foot or hand of a neonate.
- Align the emitter and detector directly opposite each other, then wrap the foam snugly without restricting circulation.
- Inspect the site regularly and move the sensor as your clinical protocol requires.
- Use on one patient only and discard after monitoring ends. Do not soak, sterilise or reprocess.
Frequently Asked Questions
What is the Masimo 2606 SpO2 sensor?
It is a disposable, non-adhesive foam wrap pulse oximetry sensor for adult and neonatal patients that uses Masimo LNCS technology to measure SpO2 and pulse rate.
How many sensors are in one box?
Each box contains 20 single-patient-use sensors. The price shown is for one box of 20.
Why choose a non-adhesive foam sensor instead of an adhesive one?
The foam wrap secures the sensor without adhesive on the skin, which reduces the risk of skin damage on neonates and on adults with fragile skin, and it can be re-wrapped during site checks.
Which monitors does this LNCS foam sensor work with?
Monitors and pulse oximeters with Masimo SET and an LNCS connection, such as Masimo Rad-8, Rad 57, Rad 87 and Radical-7, plus Masimo-equipped GE, Mindray, Datascope, Welch Allyn, Zoll and Physio-Control Lifepak models.
How long is the cable?
The sensor cable is 0.9m, approximately 3 feet.
Can this foam SpO2 sensor be reused?
No. It is a disposable sensor for single-patient use and should be discarded when monitoring of that patient ends.
Does it work with Nellcor or Masimo RD SET monitors?
No. It is designed for Masimo LNCS connections only and is not intended for Nellcor OxiMax, Nellcor Oxismart or Masimo RD SET inputs.
Related SpO2 Sensors
Need a different patient size or sensor style?
See the Masimo 2320 LNCS Neo-3 Adult/Neonate Adhesive SpO2 Sensor, the Masimo 2317 LNCS Adtx-3 Adult Adhesive SpO2 Sensor, the Masimo 2319 LNCS Inf-3 Infant SpO2 Sensor, the Masimo 3858 LNCS TFA-1 Forehead SpO2 Sensor and the reusable Masimo LNCS Neonate Wrap SpO2 Sensor 1.0m.
















Reviews