The Datex Ohmeda SAS-AP SpO2 sensor is a single-patient-use, pediatric non-woven adhesive pulse oximetry sensor built to the Datex Ohmeda SAS-AP reference specifications. It has a 0.9m (approx. 3 ft) cable with a 9-pin connector and measures oxygen saturation (SpO2) and pulse rate on Datex Ohmeda and GE patient monitors that use Ohmeda SpO2 technology. Each box contains 24 sensors.
Key Benefits of This Disposable Pediatric SpO2 Sensor
- Sized for children: The smaller pediatric wrap fits a child’s finger more securely than an adult sensor, which helps keep readings steady.
- Lower cross-contamination risk: One sensor per patient, so there is no cleaning or reprocessing between children.
- Holds on during movement: The soft non-woven adhesive keeps the emitter and detector lined up when young patients fidget.
- Gentle on skin: The breathable non-woven material is comfortable for longer monitoring periods.
- Fast, correct placement: The printed “PEDIATRIC” wrap with a finger outline shows staff where to position the finger.
- Box of 24: Good value for paediatric wards, theatres and emergency departments.
Features of the SAS-AP Pediatric Adhesive Pulse Oximeter Sensor
- Built to the Datex Ohmeda SAS-AP reference for Ohmeda SpO2 technology
- Pediatric patient size, finger application
- Non-woven adhesive sensor body with printed finger-placement guide
- 0.9m integrated cable connects to a Datex Ohmeda SpO2 extension cable
- 9-pin connector
- Single-patient use (disposable)
Datex Ohmeda SAS-AP SpO2 Sensor Specifications
| Specification | Detail |
|---|---|
| Reference / Part Number | Datex Ohmeda SAS-AP |
| Product | Disposable SpO2 Sensor |
| Patient Size | Pediatric |
| Sensor Type | Non-woven Adhesive |
| SpO2 Technology | Datex Ohmeda |
| Cable Length | 0.9m (approx. 3 ft) |
| Connector | 9-pin |
| Lifecycle | Disposable, single-patient use |
| Packaging | 24 sensors per box |
| Condition | New |
Cross-Reference Part Numbers
| Brand | Reference Number |
|---|---|
| Datex Ohmeda | SAS-AP |
| Unimed | U523-09 |
Monitors This Datex Ohmeda Pediatric SpO2 Sensor Works With
Datex Ohmeda: AS/3, Capnomac Ultima, Cardiocap I, Cardiocap II, Cardiocap/5, CG/2S, CH-RS, CH/2S, CH/S, CS/3, Light Monitor, M-ESTPR module, Oscar II, OSP-200, SAF-F, Satellite, Satellite Plus II, Satellite Trans, S/5 System, Trans Plus and the Ultima (ULT-S) series.
Please check the SpO2 reference number or connector on your current sensor or extension cable before ordering.
Use Cases for Disposable Pediatric Adhesive SpO2 Sensors
Paediatric Wards and PICU
Continuous SpO2 and pulse rate monitoring for children, where a single-use sensor supports infection control.
Paediatric Surgery and Anaesthesia
Intra-operative oximetry on Datex Ohmeda AS/3, CS/3 and S/5 anaesthesia monitors.
Recovery and PACU
Post-operative monitoring while children wake from anaesthesia and are more likely to move.
Emergency and Transport
Quick application for new paediatric admissions on Cardiocap and Satellite monitors.
How to Apply the Sensor
- Choose a finger and clean and dry the site.
- Remove the backing liner and line up the finger with the printed outline on the wrap.
- Wrap the adhesive tabs around the finger so the emitter and detector face each other.
- Connect the 9-pin connector to the monitor’s SpO2 extension cable.
- Check the site regularly and move the sensor as your facility’s protocol requires.
Frequently Asked Questions
What is the Datex Ohmeda SAS-AP SpO2 sensor?
It is a disposable pediatric non-woven adhesive SpO2 sensor built to the Datex Ohmeda SAS-AP reference. It is used for continuous pulse oximetry in children on Datex Ohmeda and GE monitors that use Ohmeda SpO2 technology.
How many sensors come in one box?
Each box contains 24 single-patient-use sensors.
What cable length and connector does it have?
The sensor has a 0.9m (about 3 ft) cable with a 9-pin connector that plugs into a Datex Ohmeda SpO2 extension cable.
Can the SAS-AP sensor be reused?
No. It is a single-patient-use disposable sensor. Dispose of it after use on one patient.
Which monitors does it work with?
Datex Ohmeda models including Cardiocap/5, AS/3, CS/3, S/5, Satellite, Satellite Plus II, Oscar II, OSP-200, Light Monitor and Capnomac Ultima. See the full list above.
What other part number matches this sensor?
Unimed U523-09 is a cross-reference for Datex Ohmeda SAS-AP.
What is the difference between SAS-AP and SAS-AF?
SAS-AP is the pediatric size and SAS-AF is the adult size. Both are non-woven adhesive disposables with a 0.9m cable for Datex Ohmeda monitors. Choose the size that matches your patient.
Related SpO2 Sensors
Looking for reusable or other adhesive options?
See the Datex Ohmeda OXY-F4-N Adult Hard Shell SpO2 Sensor 3.0m, the Datex Ohmeda All-Sizes Multi-Y SpO2 Sensor, the Datex Ohmeda OXY-W4-N Neonate Wrap SpO2 Sensor, the Nellcor MAX-I Infant Adhesive SpO2 Sensor and the Nellcor MAX-N Adult/Neonate Adhesive SpO2 Sensor.




![Datex Ohmeda Sevoflurane TEC 7 Vaporizer [Refurbished] 5 GE Datex Ohmeda TEC 7 Sevoflurane anesthesia vaporizer for precise anesthetic agent delivery in hospitals and surgical centers](https://medicalequipmentsaustralia.com.au/wp-content/uploads/2026/10/ge-datex-ohmeda-tec-7-sevoflurane-anesthesia-vaporizer-mea-100x100.webp)










Reviews
There are no reviews yet.