The BCI 1300 SpO2 sensor is a disposable, single-patient-use pulse oximetry sensor with a soft non-woven adhesive wrap, sized for adult patients. It has a 0.9m cable with a 9-pin connector and is built to the BCI 1300 reference specifications for patient monitors and pulse oximeters that use BCI (Smiths Medical) SpO2 technology. Each box contains 24 new sensors.
Key Benefits of the BCI 1300 Disposable SpO2 Sensor
- Single-patient use: A fresh sensor for every patient supports infection-control protocols and removes reprocessing between patients.
- Adult-specific fit: The adhesive finger wrap is sized and marked for adult patients for consistent emitter and detector alignment.
- Gentle on skin: Breathable non-woven adhesive tape conforms to the finger and suits extended monitoring.
- Economical bulk pack: Supplied as a box of 24 for wards, theatres, recovery and emergency departments.
- Broad monitor coverage: Works with a wide range of BCI and BCI-technology patient monitors and pulse oximeters.
Adult Adhesive Pulse Oximeter Sensor Features
- Patient size: Adult
- Sensor style: non-woven adhesive wrap
- Cable length: 0.9m (approx. 3 ft)
- Monitor-side connector: 9-pin
- SpO2 technology: BCI (Smiths Medical)
- Lifecycle: disposable
- Pack size: 24 sensors per box
BCI 1300 SpO2 Sensor Specifications
| Specification | Detail |
|---|---|
| Reference Part Number | BCI 1300 |
| Product Type | Disposable SpO2 sensor |
| Patient Size | Adult |
| Sensor Type | Non-woven adhesive |
| Cable Length | 0.9m |
| SpO2 Technology | BCI (Smiths Medical) |
| Monitor-Side Connector | 9-pin |
| Unit | 24 pcs per box |
| Lifecycle | Disposable, single-patient use |
| Condition | New |
| SKU | BCI-ADULT-NW-SPO2-9PIN-0.9M |
Part Number Cross-Reference
| Brand | Reference Number |
|---|---|
| BCI | 1300 |
| Envitec | DA-2221-1 |
| Unimed | U503-06 |
| AMC | PR-E600-1001N |
Works With These Monitors and Pulse Oximeters
- BCI: 1301, 1302, 1303, 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304 (Autocorr), 3400, 3401, 3402 (MiniCorr), 3403, 3404 (Autocorr Plus), 3444, 6100, 8400 / 8401 (Capnocheck II), 9004 (Capnocheck Plus), 9100, 9200 (Advisor), Mini Torr, Mini Torr Plus, Spectro 10, Spectro 20, SPECTRO2 10 / 20 / 30, SurgiVet, Vet/Ox Plus 4600
- Smiths Medical: SurgiVet V3304
- Armstrong: AD-900, AD-1000, AD-2000, AD-3000, AD-4000
- Artema S&W: Diascope
- ChoiceMMed: HCSMD400, MD300A, MD300I, MD300K1, MD300M, MMED6000DP-M3, -M7, -S6, -SF
- CMOS Drake: models with 9-pin connectors
- Datex Ohmeda: 4700
- Digicare: Digimax 2000, Digimax 5500
- Draeger: Oxipac 2000, Oxipac 2500
- Envitec: PulsiQuant 8040
- Goldway: UT4000A
- Infinium: Oxcyon II
- Invacare: 3300nv
- Larsen & Toubro: Cosmic, Galaxy, Planet, Planet 50, Star 50, Star 55, Stellar P
- Mennen Medical: 1300
- RGB: Omicron FT, Omicron Premium
- Spacelabs: PRO2
- Venni: VI-100A, VI-200A
- Weinmann: Oxycount Mini
Please confirm your monitor model and its SpO2 technology before ordering. An SpO2 adapter/extension cable may be required depending on your monitor.
Use Cases
- Continuous SpO2 and pulse rate monitoring in general wards, ICU and recovery
- Operating theatres and anaesthesia
- Emergency departments and patient transport
- Sleep studies and longer monitoring sessions where a clip sensor is less comfortable
- Isolation rooms where single-patient-use sensors are preferred
Application and Care
- Select an adult finger site according to your monitor’s instructions for use.
- Apply to clean, dry skin with the emitter and detector aligned opposite each other, then secure the wrap without over-tightening.
- Inspect the site regularly and reposition as clinically required.
- Dispose of the sensor after single-patient use; do not reprocess.
Frequently Asked Questions
What is the BCI 1300 SpO2 sensor used for?
It is a disposable adhesive pulse oximetry sensor used to measure oxygen saturation (SpO2) and pulse rate on adult patients with monitors that use BCI SpO2 technology.
How many sensors are in a box?
Each box contains 24 individual disposable sensors.
Is the BCI 1300 sensor reusable?
No. It is a disposable, single-patient-use sensor and should be discarded after use.
How long is the cable and what connector does it use?
The cable is 0.9m long (approximately 3 ft) and ends in a 9-pin monitor-side connector.
Which part numbers does it cross-reference to?
BCI 1300, Envitec DA-2221-1, Unimed U503-06 and AMC PR-E600-1001N.
Will it work with Nellcor or Masimo monitors?
No. It is designed for BCI (Smiths Medical) SpO2 technology only.
Related SpO2 Sensors
Need a different patient size for the same monitors?
See the BCI 1302 Adult/Neonate Adhesive SpO2 Sensor 0.9m or the BCI 1303 Infant Adhesive SpO2 Sensor 0.9m. For a reusable option, see the BCI 3444 Adult Hard Shell SpO2 Sensor 1.0m or the BCI 3444 Adult Soft Tip SpO2 Sensor 1.0m. For Nellcor OxiMax monitors, see the Nellcor MAX-A Adult Adhesive SpO2 Sensor 0.9m.
















Reviews