The Masimo 1895 LNCS TC-I is a reusable adult ear sensor for noninvasive monitoring of arterial oxygen saturation (SpO2) and pulse rate through an LNCS patient-cable connection. Its Tip-Clip design positions the optical sensor on the ear, providing an alternative measurement site when finger access is unsuitable.
Benefits of the Masimo 1895 Ear SpO2 Sensor
- Ear-clip placement supports monitoring when a finger sensor is inconvenient.
- Reusable construction helps reduce repeated consumable use.
- 0.9m (3 ft) cable provides practical reach for bedside and transport monitoring.
- LNCS technology supports connection through the appropriate LNCS patient cable.
- Lightweight Tip-Clip design supports straightforward placement and removal.
Masimo LNCS TC-I Features
Reusable Tip-Clip Ear Sensor
The sensor is designed for repeat clinical use when cleaned and disinfected in accordance with the facility’s approved protocol and the device instructions.
Adult Patient Application
Designed for patients weighing more than 30 kg. Confirm patient suitability and follow the monitor manufacturer’s instructions before use.
0.9m Sensor Cable
The integrated 3 ft cable offers useful reach while helping limit excess cable around the patient area.
Specifications
| Specification | Detail |
|---|---|
| Brand | Masimo |
| Model | LNCS TC-I |
| Part / reference number | 1895; source SKU 1895C |
| Sensor type | Reusable Tip-Clip ear SpO2 sensor |
| Patient application | Adult; patients over 30 kg |
| Measurement parameters | SpO2 and pulse rate |
| Cable length | 0.9m / 3 ft |
| Technology family | LNCS |
| Unit | 1 sensor |
| Condition | New |
Clinical Use Cases
- Hospital wards and patient-monitoring areas
- Recovery and perioperative monitoring
- Emergency and transport monitoring
- Situations where an ear measurement site is preferred
Ordering and Use Notes
Confirm that the receiving monitor, patient cable and LNCS connection are suitable before ordering. Installation and clinical use should be performed by trained healthcare personnel. Availability and delivery options apply to Australian orders.
Frequently Asked Questions
What is the Masimo 1895 LNCS TC-I?
It is a reusable Tip-Clip ear sensor used to monitor SpO2 and pulse rate in adult patients through an LNCS patient-cable connection.
What is the cable length?
The integrated cable is 0.9 metres, or approximately 3 feet, long.
Which patients is this ear sensor intended for?
It is intended for adult patients weighing more than 30 kg.
Can the Masimo 1895 sensor be reused?
Yes. It is reusable when inspected, cleaned and disinfected according to the applicable instructions and facility protocol.
Does the sensor connect directly to every monitor?
No. It requires the appropriate LNCS patient cable and a suitable monitoring system. Verify the connection and monitor requirements before purchase.
















Reviews
There are no reviews yet.