The Masimo 1864 pediatric soft tip SpO2 sensor is a reusable pulse oximetry finger sensor built to the Masimo LNCS DCI-P (1864) reference specifications.
It pairs a flexible silicone soft tip for small fingers with a 1.0m (3.3 ft) cable and an LNCS-style connector, giving continuous oxygen saturation (SpO2) and pulse rate readings on Masimo LNCS-equipped patient monitors, pulse oximeters and defibrillators.
Why Choose This Pediatric Soft Tip SpO2 Sensor?
- Child-friendly soft tip: A one-piece silicone sleeve wraps gently around a child’s finger, spreading pressure more evenly than a rigid clip for longer monitoring sessions.
- Masimo LNCS technology: Built to the LNCS DCI-P reference, so it plugs straight into LNCS SpO2 ports and LNCS patient cables.
- Reusable and cost-effective: One sensor serves many patients after routine cleaning, lowering cost per use versus single-use adhesive sensors.
- Short 1.0m cable: Reduces cable clutter at the bedside and connects neatly to an LNCS extension cable where needed.
- Certified quality:
- Brand new condition: Supplied new, 1 piece per bag.
Masimo 1864 SpO2 Sensor Specifications
| Specification | Detail |
|---|---|
| Reference Model | Masimo 1864 (LNCS DCI-P) |
| Cross-Reference | Unimed U103S-49R |
| SpO2 Technology | Masimo LNCS |
| Patient Size | Pediatric |
| Sensor Type | Soft Tip (silicone finger sensor) |
| Cable Length | 1.0m (3.3 ft) |
| Lifecycle | Reusable |
| Unit | 1 pc per bag |
| Warranty | 12 Months |
| Condition | New |
Part Number Cross-Reference
| Brand | Reference Number |
|---|---|
| Masimo | 1864, LNCS DCI-P |
| Unimed | U103S-49R |
Monitors This LNCS Pediatric SpO2 Sensor Works With
This sensor works with equipment that accepts Masimo LNCS sensors, including the following OEM models. Always confirm your device’s SpO2 port type before ordering.
- Bitmos: sat 800, sat 801, sat 805, sat 816, satPuls
- Comen: K12 Pro
- Datascope: Accutor V, Accutorr 3, Accutorr 7, Accutorr Plus, DPM4, DPM6, DPM7, EPM4, MEC 12, MPM, Passport 2LT, Passport XG, PM 6800, T8, V12, V21, VS 800
- Datex Ohmeda: Giraffe Infant Warmer, S/5
- Draeger: Infinity M540, Narkomed 6400
- GE Healthcare: 128, 250, 250cx, B125, B125M, B40, Carescape B650, Carescape B850, Carescape V100 (Masimo), Dash Series, Dinamap ProCare with Masimo, Pro 1000, Pro 300V2, ProCare 300, ProCare Auscultatory 400, ProSeries V2, SOLAR Series, TRAM 450SL, V300
- Invivo: Escort II OPT30 Prism
- Marquette: 8000 e Eagle 1000, Dash 2000, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Eagle, i/9500, i/9500 (Tram 451N5/851N5), PDM Module, Procare B40, Smk SMV, SOLAR, Solar 7000, Solar 8000, Solar 8000M, Tram 451, TRAM Modular, x50SL Series
- Masimo: Pronto 7, Rad 5, Rad 57, Rad 87, Rad-8, Radical-7
- Mennen Medical: Horizon XVu
- Mindray: Accutorr V, BeneHeart D6, BeneView T1, BeneView T5, BeneView T8, Duo, IPM Series, Passport 12, Passport 2, Passport 8, Passport V, PM 6000, PM 7000, PM 8000, PM 9000, Spectrum, Spectrum OR, TM80, Trio
- Philips: IntelliVue MX700 (Masimo Rainbow)
- Physio-Control: Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E
- Respironics: Alice 5
- Welch Allyn: 1500, 45NE0-E1 LX, Propaq CS, Propaq LT, Spot Vital Signs 42MTB-E1, Spot Vital Signs LXi
- Zoll: E Series, M Series, R Series, X Series
Clinical Use Cases
Pediatric Wards and PICU
Continuous SpO2 and pulse rate monitoring for children on bedside monitors such as Mindray BeneView, GE Carescape and Datascope Passport.
Emergency and Transport
Ideal for pediatric use with Zoll and Physio-Control Lifepak defibrillator/monitors in ambulances, emergency departments and inter-hospital transfers.
Spot-Checks, Clinics and Sleep Labs
Fits Masimo Rad-series and Welch Allyn Spot Vital Signs devices for outpatient checks, plus Respironics Alice 5 sleep diagnostics.
Care and Cleaning
- Disconnect the sensor from the monitor before cleaning.
- Wipe the soft tip and cable with a soft cloth dampened with 70% isopropyl alcohol or a mild hospital disinfectant.
- Do not immerse the connector or autoclave the sensor.
- Let the sensor dry fully before reuse, and check the cable and tip for damage.
- Reposition the sensor at least every 4 hours and check skin integrity, particularly on young patients.
Frequently Asked Questions
What is the Masimo 1864 SpO2 sensor?
The Masimo 1864 is the LNCS DCI-P pediatric reusable finger sensor reference. This soft tip version is built to the same specifications and measures oxygen saturation and pulse rate on LNCS monitors.
Which patients is this sensor designed for?
It is sized for pediatric patients (children). For adults, choose an adult sensor; for infants and neonates, use a wrap-style sensor.
What is the difference between the soft tip and hard shell 1864 sensors?
Both follow the LNCS DCI-P reference. The soft tip uses a flexible silicone sleeve that is gentler for long monitoring, while the hard shell uses a rigid spring clip that is quick to apply for spot-checks.
Will it work with my monitor?
It works with devices that accept Masimo LNCS sensors, including Masimo Rad-series, GE Carescape and Dash, Mindray BeneView, Zoll and Lifepak units. Monitors with Masimo M-LNCS or Rainbow ports may need the matching adapter cable.
Is this sensor reusable?
Yes. It is a reusable sensor that can be cleaned and disinfected between patients according to your facility’s protocol.
How long is the cable?
The cable is 1.0 m (3.3 ft). Add an LNCS patient extension cable if you need more reach.
Does it come with a warranty?
Yes, a 12-month warranty covers the sensor. It is supplied new, 1 piece per bag.
Related SpO2 Sensors
Shop related sensors: Masimo 1864 Pediatric Hard Shell SpO2 Sensor 1.0m, Neonate Wrap SpO2 Sensor 1.0m Masimo LNCS, Masimo 1269 LNOP DCI Adult Hard Shell SpO2 Sensor, Nellcor FLEXMAX-P Pediatric Soft Tip SpO2 Sensor and Nonin 8000SS Infant Soft Tip SpO2 Sensor.
















Reviews
There are no reviews yet.