The Masimo 1896 LNCS TF-I forehead SpO2 sensor is a new, reusable pulse oximetry sensor with a 1.0m cable, built to the Masimo 1896 (LNCS TF-I) and Draeger MP00799 reference specifications. It sits on the patient’s forehead rather than a finger, connects to Masimo LNCS technology patient monitors and pulse oximeters, and is rated for all patient sizes.
Key Benefits of This LNCS Forehead Pulse Oximetry Sensor
- Alternative monitoring site: The forehead placement is useful when fingers are unavailable or unsuitable for a clip sensor.
- One sensor, all patient sizes: A single reusable forehead sensor covers the full patient range, reducing the number of sensor types to stock.
- Reusable design: Cleaned between patients and reused, lowering cost per use versus single-patient adhesive sensors.
- Broad monitor coverage: Works with Masimo LNCS equipped monitors from Masimo, GE Healthcare, Marquette, Mindray, Datascope, Welch Allyn, Zoll, Physio-Control and more.
- 12-month warranty
Features
- Forehead sensor style, patient size: all sizes
- 1.0m (approx. 3.3 ft) cable
- Masimo LNCS SpO2 technology connector
- Reusable lifecycle
- Supplied new, 1 set per bag
Technical Specifications
| Specification | Detail |
|---|---|
| Reference Part Number | Masimo 1896 (LNCS TF-I) |
| Sensor Type | Forehead |
| Patient Size | All Sizes |
| SpO2 Technology | Masimo LNCS |
| Cable Length | 1.0m (3.3 ft) |
| Lifecycle | Reusable |
| Condition | New |
| Unit | 1 set / bag |
| Warranty | 12 Months |
Part Number Cross-Reference
| Brand | Reference Number |
|---|---|
| Masimo | 1896, LNCS TF-I |
| Draeger | MP00799 |
Works With These Patient Monitors
| Brand | Models |
|---|---|
| Masimo | Pronto 7, Rad 5, Rad 57, Rad 87, Rad-8, Radical-7 |
| GE Healthcare | B125, B125M, B40, Carescape B650, Carescape B850, Carescape V100 (Masimo technology), Dash Series, Dinamap ProCare with Masimo, Pro 300V2, ProCare 300, ProCare Auscultatory 400, ProSeries V2, SOLAR Series, TRAM 450SL, V300, 250, 250cx |
| Marquette | Dash 2000, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Eagle, Eagle 1000, PDM Module, Procare B40, SOLAR, Solar 7000, Solar 8000, Solar 8000M, Tram 451, TRAM Modular, x50SL Series |
| Mindray | Accutorr V, BeneHeart D6, BeneView T1, BeneView T5, BeneView T8, Duo, IPM Series, Passport 12, Passport 2, Passport 8, Passport V, PM 6000, PM 7000, PM 8000, PM 9000, Spectrum, Spectrum OR, TM80, Trio |
| Datascope | Accutorr V, Accutorr 3, Accutorr 7, Accutorr Plus, DPM4, DPM6, DPM7, EPM4, MEC 12, MPM, Passport 2LT, Passport XG, PM 6800, T8, V12, V21, VS 800 |
| Draeger | Infinity M540, Narkomed 6400 |
| Datex Ohmeda | Giraffe Infant Warmer, S/5 |
| Welch Allyn | 1500, 45NE0-E1 LX, Propaq CS, Propaq LT, Spot Vital Signs 42MTB-E1, Spot Vital Signs LXi |
| Zoll | E Series, M Series, R Series, X Series |
| Physio-Control | Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E |
| Philips | IntelliVue MX700 (Masimo Rainbow) |
| Bitmos | sat 800, sat 801, sat 805, sat 816, satPuls |
| Other | Comen K12 Pro, Invivo Escort II OPT30 Prism, Mennen Medical Horizon XVu, Respironics Alice 5 |
The monitor must be fitted with Masimo LNCS SpO2 technology. Please confirm your monitor’s SpO2 technology and connector before ordering.
Use Cases
- Spot-check and continuous SpO2 and pulse rate monitoring in hospitals, clinics and day surgeries
- Patients where a finger sensor is impractical
- Emergency and transport monitoring with LNCS equipped defibrillator/monitors
- Sleep study and bedside monitoring
- Biomedical engineering spares and replacement sensor stock
Application and Care
- Place the sensor flat on clean, dry forehead skin and secure it as directed by your monitor’s instructions for use.
- Check the application site regularly and reposition as clinically required.
- Wipe clean and disinfect between patients according to your facility protocol; do not immerse or autoclave.
- Inspect the cable and sensor for damage before each use.
Frequently Asked Questions
What is the Masimo 1896 LNCS TF-I sensor?
1896 is the Masimo reference number for the LNCS TF-I reusable forehead SpO2 sensor. This product is a new forehead sensor built to that reference specification, with a 1.0m cable and Masimo LNCS technology.
Is this sensor reusable?
Yes. It is a reusable sensor intended to be cleaned and used on multiple patients.
Which patient sizes can it be used on?
It is specified for all patient sizes.
Will it work with my monitor?
It works with monitors that use Masimo LNCS SpO2 technology, including the Masimo Radical-7, Rad-8 and Rad 57, GE Dash and Solar series, Mindray BeneView and Passport series, Zoll and Lifepak units listed above. It will not work with Nellcor, Philips FAST or Masimo RD SET ports without the correct adapter cable.
How long is the cable?
The cable length is 1.0m (about 3.3 ft).
Does it come with a warranty?
Yes, it is supplied new with a 12-month warranty.
Related SpO2 Sensors
Also see the Masimo 1895 LNCS TC-I Ear SpO2 Sensor, the Masimo 1864 Pediatric Hard Shell SpO2 Sensor 1.0m, the Masimo LNCS Infant Soft Tip SpO2 Sensor 1.0m, the Nellcor MAXFAST Forehead SpO2 Sensor 1.0m and the Philips FAST Forehead SpO2 Sensor 2.0m.
















Reviews