The GE OXY-E-UN Ear Clip SpO2 Sensor is a new, reusable adult pulse oximetry sensor with a 1.0 m cable and an 8 pin connector, built to the GE Healthcare / Datex Ohmeda OXY-E-UN reference specifications. It clips to the earlobe and works with GE OxyTip+ technology monitors to measure blood oxygen saturation (SpO2) and pulse rate.
Key Benefits of the OXY-E-UN Ear Clip Pulse Oximeter Sensor
- Reliable alternative measurement site: The earlobe often gives a steadier signal when fingers are cold, poorly perfused or moving.
- Hands stay free: Useful during procedures, transport and stress testing where finger sensors get in the way.
- Reusable design: Wipe-clean construction lowers the cost per patient compared with single-use sensors.
- Direct fit: 8 pin OxyTip+ connector plugs into the matching GE and Datex Ohmeda interconnect cable or monitor port.
- 12 month warranty for peace of mind.
Features
- Adult ear clip sensor style with soft, lightweight clip
- GE OxyTip+ SpO2 technology
- 1.0 m (approx. 3.3 ft) flexible cable
- 8 pin connector
- Reusable, latex-free patient contact design
Technical Specifications
| Specification | Detail |
|---|---|
| Reference Part Number | OXY-E-UN |
| Brand Reference | GE Healthcare / Datex Ohmeda |
| Sensor Type | Ear Clip |
| Patient Size | Adult |
| SpO2 Technology | GE OxyTip+ |
| Cable Length | 1.0 m (3.3 ft) |
| Connector | 8 Pin |
| Lifecycle | Reusable |
| Condition | New |
| Unit | 1 pc per bag |
| Warranty | 12 Months |
Part Number Cross-Reference
| Brand | Reference Number |
|---|---|
| GE Healthcare | OXY-E-UN |
| Datex Ohmeda | OXY-E-UN |
| Envitec | ES-3003-9 |
| Unimed | U903-127 |
| Praymed | PSG0123-S |
Works With These GE and Datex Ohmeda Monitors
Datex Ohmeda
- 3755, 37xx Series, 3800, 3900, 3900P, 4700, 5250, Biox 3700
- AS/3 with M-OSAT module, CS/3 with M-OSAT module, S/5 with M-OSAT module
- Cardiocap AS/3 (N-XOSAT), Cardiocap S/5, Cardiocap/5
- S/5 and i4 with E-series modules, E-PRESTN
- TruSat, TruSat TD, TruSignal, TuffSat
GE Healthcare
- Aisys, Aisys CS2
- Carescape B650, Carescape V100
- 259 Series
Always confirm your monitor’s SpO2 technology and connector before ordering.
Use Cases
- Spot checks and continuous SpO2 monitoring in hospitals and clinics
- Anaesthesia, recovery and procedural sedation
- Patients with low peripheral perfusion or cold extremities
- Exercise and stress testing where hand movement affects finger readings
Application and Care
- Place the clip on the fleshy part of the earlobe, away from cartilage and jewellery.
- Rubbing the earlobe for a few seconds before placement can improve the signal.
- Check the site regularly and reposition during long monitoring sessions.
- Clean with a soft cloth and a mild disinfectant between patients. Do not soak, autoclave or immerse the connector.
Frequently Asked Questions
What is the GE OXY-E-UN ear clip SpO2 sensor used for?
It measures blood oxygen saturation and pulse rate at the earlobe of adult patients on GE Healthcare and Datex Ohmeda monitors that use OxyTip+ technology.
Which monitors does the OXY-E-UN ear sensor work with?
It works with Datex Ohmeda 3800, 3900, 3900P, TruSat, TuffSat, Cardiocap/5 and S/5 systems, plus GE Aisys, Aisys CS2, Carescape B650 and Carescape V100, among the models listed above.
How long is the cable and what connector does it have?
The cable is 1.0 metre (about 3.3 feet) long and ends in an 8 pin OxyTip+ connector.
When should I choose an ear clip sensor instead of a finger sensor?
Choose an ear clip when finger readings are unreliable because of poor circulation, cold hands or movement, or when the hands are not accessible.
Can this SpO2 sensor be reused?
Yes. It is a reusable sensor that can be wiped clean and disinfected between patients.
Related SpO2 Sensors
Need a different style?
See the GE OxyTip+ Adult Hard Shell SpO2 Sensor 1.0m, the GE OxyTip+ Adult Soft Tip SpO2 Sensor 1.0m, the GE OXY-AP Pediatric Adhesive SpO2 Sensor or the GE TruSignal TS-F4-MC Adult Hard Shell SpO2 Sensor 3.0m.
















Reviews
There are no reviews yet.