The Datex Ohmeda OXY-E-DB adult ear clip SpO2 sensor is a reusable pulse oximetry sensor with a 1.0m cable and a 9-pin connector that clips to the earlobe to measure oxygen saturation (SpO2) and pulse rate on Datex Ohmeda patient monitors. This brand-new sensor is built to the OXY-E-DB reference specifications and uses Datex Ohmeda SpO2 technology, making it a practical choice when finger sites are unavailable or poorly perfused.
Key Benefits of the OXY-E-DB Ear Clip Pulse Oximetry Sensor
- Alternative monitoring site: The earlobe gives a dependable reading when fingers are cold, injured, bandaged or subject to motion.
- Reusable design: Lowers cost per patient compared with single-use adhesive sensors.
- Direct connection: The 9-pin plug matches Datex Ohmeda monitors that accept OXY-E-DB style sensors.
- Short 1.0m lead: Reduces cable clutter at the bedside, in theatre and during transport.
- Peace of mind: Supplied new with a 12-month warranty.
Features
- Adult ear clip sensor style with a lightweight spring clip
- Datex Ohmeda SpO2 technology
- 9-pin D-type monitor connector with orientation marker
- 1.0m (3.3 ft) flexible grey cable
- Reusable lifecycle – wipe clean between patients
Technical Specifications
| Specification | Detail |
|---|---|
| Reference Part Number | Datex Ohmeda OXY-E-DB |
| Product Type | Replacement SpO2 sensor (non-OEM) |
| Sensor Type | Ear Clip |
| Patient Size | Adult |
| SpO2 Technology | Datex Ohmeda |
| Connector | 9-Pin |
| Cable Length | 1.0m (3.3 ft) |
| Lifecycle | Reusable |
| Condition | New |
| Unit | 1 pc per bag |
| Warranty | 12 Months |
| SKU | DO-OXYEDB-SPO2-EC-9P-1M |
Part Number Cross-Reference
| Brand | Reference Number |
|---|---|
| Datex Ohmeda | OXY-E-DB |
| Unimed | U903-09 |
| AMC | PR-A220-1005N |
Works With These Datex Ohmeda Monitors
- AS/3, CS/3, System 5
- Cardiocap I, Cardiocap II, Cardiocap/5
- Capnomac Ultima (ULTS00, ULTSIO, ULTSVI, ULTSVO)
- CG/2S, CH/S, CH/2S, CH-RS
- Light Monitor, M-ESTPR module, Oscar II, OSP-200, SAF-F
- Satellite, Satellite Plus II, Satellite Trans, Trans Plus
Always confirm the reference number and connector on your existing sensor before ordering.
Use Cases
- Anaesthesia and operating theatre monitoring
- Recovery, ICU and general ward spot checks or continuous monitoring
- Patients with low peripheral perfusion, nail polish or finger injuries
- Biomedical engineering departments replacing worn or damaged sensors
Application and Care
- Clip the sensor onto the fleshy part of the earlobe; gently rub the lobe first to improve perfusion.
- Route the cable so it does not pull on the clip.
- Clean between patients by wiping with a soft cloth and a mild disinfectant such as 70% isopropyl alcohol. Do not immerse, autoclave or soak.
- Inspect the cable and clip before each use and replace if damaged.
Frequently Asked Questions
What is the Datex Ohmeda OXY-E-DB ear clip SpO2 sensor used for?
It measures blood oxygen saturation and pulse rate at the earlobe of adult patients connected to Datex Ohmeda monitors that accept OXY-E-DB style 9-pin sensors.
Which monitors does this ear clip sensor work with?
It works with Datex Ohmeda AS/3, CS/3, System 5, Cardiocap I, II and /5, Capnomac Ultima, Satellite series, Light Monitor, Oscar II and OSP-200 monitors, among others listed above.
How long is the cable?
The cable is 1.0 metre (about 3.3 feet) long.
When should I choose an ear clip sensor instead of a finger sensor?
Choose an ear clip when finger readings are unreliable due to poor circulation, cold hands, movement, or when the hands are not accessible during a procedure.
Can the sensor be reused?
Yes. It is a reusable sensor and can be wiped clean and disinfected between patients.
Related SpO2 Sensors
Need a different style or length?
See the Datex Ohmeda OXY-F-DB Adult Hard Shell SpO2 Sensor 1.0m, the Datex Ohmeda OXY-E4-N Adult Ear Clip SpO2 Sensor 3.0m, the GE TruSignal Adult Ear Clip SpO2 Sensor 1.0m, the Datex Ohmeda All-Sizes Multi-Y SpO2 Sensor 3.0m and the Datex Ohmeda OXY-F4-N Adult Hard Shell SpO2 Sensor 3.0m.
















Reviews