The Datex Ohmeda pediatric SpO2 sensor is a reusable hard shell finger clip pulse oximetry sensor built to Datex Ohmeda SpO2 technology specifications.
It connects directly to Datex Ohmeda and GE Healthcare patient monitors through a 10-pin round connector and a 3.0 m (approx. 9.8 ft) cable, delivering continuous oxygen saturation (SpO2) and pulse rate readings for pediatric patients.
Key Benefits of This Pediatric Pulse Oximetry Sensor
- Sized for children: Pediatric hard shell finger clip gives a secure, comfortable fit on smaller fingers.
- Direct connection: 10-pin round connector plugs straight into Datex Ohmeda SpO2 ports — no adapter cable required.
- Long 3.0 m cable: Extra reach between bedside, cot or transport stretcher and the monitor.
- Reusable and cost-effective: Durable hard shell housing withstands repeated cleaning between patients.
- Quality backed:
Features of the Reusable Datex Ohmeda SpO2 Finger Sensor
Hard Shell Finger Clip Design
The rigid shell and spring hinge hold the LED emitter and photodetector in consistent alignment, reducing ambient-light interference and motion-related signal loss during spot checks and continuous monitoring.
Datex Ohmeda SpO2 Technology
Calibrated for Datex Ohmeda oximetry, so readings are processed natively by the host monitor’s SpO2 module for accurate saturation and pulse rate display.
10-Pin Round Connector
The round 10-pin plug matches the SpO2 input found on Datex Ohmeda S/5, AS/3, CS/3 and Cardiocap series monitors and modules.
Datex Ohmeda Pediatric SpO2 Sensor Specifications
| Specification | Detail |
|---|---|
| Product Type | Reusable SpO2 Sensor |
| Patient Size | Pediatric |
| Sensor Type | Hard Shell Finger Clip |
| SpO2 Technology | Datex Ohmeda |
| Connector | 10-pin round |
| Cable Length | 3.0 m (approx. 9.8 ft) |
| Lifecycle | Reusable |
| Unit | 1 piece per bag |
| Warranty | 12 Months |
| Condition | New |
Cross-Reference Part Number
| Brand | Reference Number |
|---|---|
| Unimed | U110-09 |
Monitors This Pediatric SpO2 Sensor Works With
Datex Ohmeda
Aespire, Aespire 15, AS/3, AS/3 Compact, AS/3 with M-series modules, Capnomac Ultima, Cardiocap I, Cardiocap II, Cardiocap S/5 Light, Cardiocap/5, CG/2S, CH-RS, CH/2S, CH/S, CS/3, CS/3 with M-series modules, CS/5, CS/5 Compact, Light Monitor, M-ESTP, M-NESTPR, M-PRESTN, Oscar II, OSP-200, S/5, S/5 with M-series modules, Satellite, Satellite Plus II, Satellite Trans, System 5, Trans Plus, TruSignal, ULTS00, ULTSIO, ULTSVI, ULTSVO
GE Healthcare
Datex Ohmeda S5
Always confirm your monitor model and SpO2 connector before ordering.
Clinical Use Cases
- Pediatric wards and paediatric intensive care units (PICU)
- Operating theatres and anaesthesia workstations (Aespire, S/5)
- Post-anaesthesia recovery (PACU) and emergency departments
- Intra-hospital patient transport with Datex Ohmeda transport monitors
- Outpatient clinics and day surgery units
Care and Maintenance
- Wipe the sensor and cable with a soft cloth dampened with 70% isopropyl alcohol or a mild hospital-grade disinfectant between patients.
- Do not immerse, autoclave or gas-sterilise the sensor.
- Inspect the cable and connector for damage before each use; do not pull on the cable to disconnect.
- Reposition the sensor site regularly during extended monitoring to protect the patient’s skin.
Frequently Asked Questions
Which monitors does this Datex Ohmeda pediatric SpO2 sensor work with?
It works with Datex Ohmeda and GE Healthcare monitors that use Datex Ohmeda SpO2 technology and a 10-pin round SpO2 connector, including S/5, AS/3, CS/3, Cardiocap/5, Light Monitor and Aespire systems.
Is this pediatric pulse oximeter sensor reusable?
Yes. It is a reusable hard shell finger clip sensor designed for repeated use after cleaning between patients.
How long is the cable?
The cable is 3.0 metres (about 9.8 feet), connecting directly to the monitor without an extension cable.
What patient size is it designed for?
It is sized for pediatric patients. For adults, choose an adult hard shell sensor; for neonates, choose a neonate wrap sensor.
Does it need an adapter cable?
No. The 10-pin round connector plugs directly into Datex Ohmeda SpO2 inputs.
What is the cross-reference part number?
This sensor cross-references Unimed U110-09.
Is the sensor new, and does it include a warranty?
Yes.
Related SpO2 Sensors
Complete your Datex Ohmeda monitoring setup: Datex Ohmeda OXY-W4-N Neonate Wrap SpO2 Sensor 3.0m, Datex Ohmeda All-Sizes Multi-Y SpO2 Sensor 3.0m, Datex Ohmeda OXY-F-DB Adult Hard Shell SpO2 Sensor, GE OxyTip+ Adult Hard Shell SpO2 Sensor 1.0m and Masimo 1864 Pediatric Hard Shell SpO2 Sensor.
















Reviews
There are no reviews yet.