For Repair Ultrasound & Endoscopic Probes Contact: sales@medicalequipmentsaustralia.com.au
Prices Include GST | Contact Us for International Shipping

Masimo 4055 RD SET TF-I All Sizes Forehead SpO2 Sensor 1.0m (Reusable New)

You Will Receive The Following:

1 x All Sizes Forehead SpO2 Sensor, 1.0m cable (1 set per bag)

QTY: 1

Condition: New

Cross-Reference: Masimo 4055 (RD SET TF-I), Draeger MS40073

Technology: Masimo RD SET

| Reusable

12-Month Warranty

EXPRESS SHIPPING

$280.00 Including GST

- +

Have Questions? Contact Us

Shop With Confidence
  • Fast Delivery (2–5 Business Days)
  • No-Risk Money-Back Guarantee
  • No Hassle Refunds
  • 100% Secure Payments
  • 24/7 Customer Support
  • Fully Tracked Shipping
Guaranteed Safe Checkout

Medical Equipments Australia does not provide medical advice, diagnosis, or treatment. Products sold on this website are not intended to replace professional medical advice. Always consult a qualified healthcare professional regarding any medical condition or the use of medical equipment.

The Masimo 4055 RD SET TF-I forehead SpO2 sensor is a new, reusable pulse oximetry sensor with a 1.0m cable, built to the Masimo 4055 (RD SET TF-I) and Draeger MS40073 reference specifications. It is applied to the patient’s forehead instead of a finger, plugs into Masimo RD SET patient cables and monitor ports, and is specified for all patient sizes.

Key Benefits of This RD SET Forehead Pulse Oximetry Sensor

  • Alternative monitoring site: Forehead placement is useful when fingers are unavailable or unsuitable for a clip sensor.
  • One sensor, all patient sizes: A single reusable forehead sensor covers the full patient range, so there are fewer sensor types to stock.
  • Reusable design: Cleaned between patients and used again, lowering cost per use compared with single-patient adhesive sensors.
  • Masimo RD SET connection: Flat RD style plug for Masimo RD SET patient cables and RD equipped monitors.
  • 12-month warranty: Supplied new and covered for 12 months.

Features of the Masimo RD SET TF-I Reusable Forehead Sensor

  • Forehead sensor style, patient size: all sizes
  • 1.0m (approx. 3.3 ft) cable
  • Masimo RD SpO2 technology connector
  • Reusable lifecycle
  • Supplied new, 1 set per bag

Technical Specifications

SpecificationDetail
Reference Part NumberMasimo 4055 (RD SET TF-I)
Sensor TypeForehead
Patient SizeAll Sizes
SpO2 TechnologyMasimo RD (RD SET)
Cable Length1.0m (3.3 ft)
LifecycleReusable
ConditionNew
Unit1 set / bag
Warranty12 Months

Part Number Cross-Reference

BrandReference Number
Masimo4055, RD SET TF-I
DraegerMS40073

Works With Masimo RD SET Equipment

This forehead sensor works with patient monitors, pulse oximeters and patient cables that use the Masimo RD SET sensor connection. Please confirm your monitor’s SpO2 technology and connector type before ordering. It does not plug directly into Masimo LNCS, M-LNCS or LNOP ports, Nellcor ports or Philips FAST ports.

Use Cases

  • Spot-check and continuous SpO2 and pulse rate monitoring in hospitals, clinics and day surgeries
  • Patients where a finger sensor is impractical
  • Bedside, recovery and procedural monitoring on RD SET equipped monitors
  • Biomedical engineering spares and sensor stock for RD SET fleets

Application and Care

  • Place the sensor flat on clean, dry forehead skin and secure it as directed by your monitor’s instructions for use.
  • Check the application site regularly and reposition as clinically required.
  • Wipe clean and disinfect between patients according to your facility protocol.
  • Inspect the cable and sensor for damage before each use.

Frequently Asked Questions

What is the Masimo 4055 RD SET TF-I sensor?

4055 is the Masimo reference number for the RD SET TF-I reusable forehead SpO2 sensor. This product is a new forehead sensor built to that reference specification, with a 1.0m cable and a Masimo RD technology connector.

Is the RD SET TF-I forehead sensor reusable?

Yes. It is a reusable sensor intended to be cleaned and used on multiple patients.

Which patient sizes can this forehead SpO2 sensor be used on?

It is specified for all patient sizes.

Will it work with my patient monitor?

It works with monitors and patient cables that use the Masimo RD SET sensor connection. It will not plug directly into Masimo LNCS, M-LNCS or LNOP, Nellcor or Philips FAST ports, so check your connector before ordering.

What is the difference between Masimo 4055 RD SET TF-I and Masimo 1896 LNCS TF-I?

Both are reusable forehead SpO2 sensors. The 4055 uses the Masimo RD SET connector, while the 1896 uses the older Masimo LNCS connector. Choose the one that matches your patient cable or monitor port.

How long is the cable?

The cable length is 1.0m (about 3.3 ft).

Does it come with a warranty?

Yes, it is supplied new with a 12-month warranty.

Related SpO2 Sensors

Also see the Masimo 1896 LNCS TF-I Forehead SpO2 Sensor 1.0m, the Masimo 4052 RD SET DBI Adult Soft Tip SpO2 Sensor 1.0m, the Nellcor MAXFAST Forehead SpO2 Sensor 1.0m, the Philips FAST Forehead SpO2 Sensor 2.0m and the BCI All Sizes Forehead SpO2 Sensor 1.0m.

Reviews

There are no reviews yet.

Be the first to review “Masimo 4055 RD SET TF-I All Sizes Forehead SpO2 Sensor 1.0m (Reusable New)”

Your email address will not be published. Required fields are marked *

Masimo 4055 RD SET TF-I forehead SpO2 sensor 1.0m reusable all sizesMasimo 4055 RD SET TF-I forehead SpO2 sensor 1.0m reusable all sizesMasimo 4055 RD SET TF-I All Sizes Forehead SpO2 Sensor 1.0m (Reusable New)
$280.00 Including GST
- +

Have Questions? Contact Us

Shop With Confidence
  • Fast Delivery (2–5 Business Days)
  • No-Risk Money-Back Guarantee
  • No Hassle Refunds
  • 100% Secure Payments
  • 24/7 Customer Support
  • Fully Tracked Shipping
Scroll to Top