The BCI 3044 Adult Hard Shell SpO2 Sensor is a reusable adult finger clip pulse oximetry probe built to the BCI 3044 reference specifications for Smiths Medical BCI SpO2 technology.
It features a rigid hard shell finger housing, a 9-pin connector and an extended 3.0m (approx. 9.8 ft) cable, and is designed for continuous or spot-check oxygen saturation (SpO2) and pulse rate monitoring on adult patients.
Key Benefits of This BCI Adult Finger Clip SpO2 Sensor
- Extended 3.0m cable longer reach than the 3 ft OEM length, so monitors can sit further from the bed or chair.
- Hard shell finger clip durable spring-loaded housing that holds the finger securely and shields the optics from ambient light.
- Reusable and cost-effective cleanable between patients, reducing per-use cost against disposable probes.
- Plug-and-play 9-pin connector connects directly to BCI-technology monitors and oximeters that accept 9-pin SpO2 sensors.
- Backed by a 12-month warranty
Features of the BCI 3044 Reusable SpO2 Probe
Adult Hard Shell Design
The rigid finger clip suits adult patients in the recommended weight range for adult finger sensors and is ideal for short-term monitoring, spot checks and patient transport.
Smiths Medical BCI SpO2 Technology
The sensor is built to work with BCI oximetry algorithms, providing reliable SpO2 and pulse rate readings on monitors that use Smiths Medical BCI technology.
Long 3.0m Patient Cable
The 3.0m cable gives extra freedom of movement for the patient and flexible monitor placement in wards, clinics and procedure rooms.
BCI 3044 SpO2 Sensor Specifications
| Specification | Detail |
|---|---|
| Product | Adult Hard Shell (Finger Clip) SpO2 Sensor |
| Reference Model | BCI 3044 (OEM cable length 3 ft) |
| Condition | New |
| SpO2 Technology | Smiths Medical BCI |
| Patient Size | Adult |
| Sensor Type | Hard shell finger clip |
| Cable Length | 3.0m (approx. 9.8 ft) |
| Connector | 9-pin |
| Lifecycle | Reusable |
| Unit | 1 piece per bag |
| Warranty | 12 months |
Cross-Reference Part Numbers
| Brand | Reference Number |
|---|---|
| BCI | 3044 (OEM is 3 ft) |
| Unimed | U410-06 |
Monitors and Oximeters This SpO2 Sensor Works With
- BCI / Smiths Medical: 1301, 1302, 1303, 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3304 Autocorr, 3400, 3401, 3402 MiniCorr, 3403, 3404, 3404 Autocorr Plus, 3444, 6100, 8400 / 8401 Capnocheck II, 9004 Capnocheck Plus, 9100, 9200 Advisor, Mini Torr, Mini Torr Plus, Spectro2 10 / 20 / 30, SurgiVet V3304, Vet/Ox Plus 4600
- Armstrong: AD-900, AD-1000, AD-2000, AD-3000, AD-4000
- Artema S&W: Diascope
- ChoiceMMed: HCSMD400, MD300A, MD300I, MD300K1, MD300M, MMED6000DP-M3, MMED6000DP-M7, MMED6000DP-S6, MMED6000DP-SF
- CMOS Drake: All models with 9-pin SpO2 connectors
- Datex Ohmeda: 4700
- Digicare: Digimax 2000, Digimax 5500
- Draeger: Oxipac 2000, Oxipac 2500
- Envitec: PulsiQuant 8040
- Goldway: UT4000A
- Infinium: Oxcyon II
- Invacare: 3300nv
- Larsen & Toubro: Cosmic, Galaxy, Planet, Planet 50, Star 50, Star 55, Stellar P
- Mennen Medical: 1300
- RGB: Omicron FT, Omicron Premium
- Spacelabs: PRO2
- Venni: VI-100A, VI-200A
- Weinmann: Oxycount Mini
Please confirm your monitor’s connector and SpO2 technology before ordering. Brand names and model numbers are used for identification purposes only.
Common Use Cases
- Hospital wards, recovery rooms and step-down units
- Anaesthesia, capnography and pulse oximetry stations using BCI technology
- Emergency departments, clinics and GP practices
- Home care, sleep studies and long-term care facilities
- Veterinary monitoring on BCI-based SurgiVet and Vet/Ox units
Care and Maintenance
- Wipe the sensor and cable with a soft cloth dampened with 70% isopropyl alcohol or a mild hospital-grade disinfectant between patients.
- Do not immerse, autoclave or gas-sterilise the sensor.
- Avoid sharply bending or pulling the cable; coil loosely for storage.
- Reposition the finger clip every 2–4 hours during continuous monitoring to protect skin integrity.
Frequently Asked Questions
What is the BCI 3044 SpO2 sensor?
It is a reusable adult finger clip (hard shell) pulse oximetry sensor that measures SpO2 and pulse rate on monitors using Smiths Medical BCI oximetry technology.
How long is the cable on this sensor?
This version has a 3.0m (about 9.8 ft) cable, which is longer than the 3 ft cable of the original BCI 3044 reference.
What connector does this BCI SpO2 sensor use?
It uses a 9-pin connector that plugs directly into BCI-technology monitors and oximeters.
Is this SpO2 sensor reusable?
Yes. It is a reusable sensor that can be cleaned and disinfected between patients.
Which patients is it suitable for?
It is designed for adult patients. For children or neonates, choose a pediatric, infant or neonate sensor.
Is the sensor new?
Yes. Every unit is supplied brand new, individually bagged, with a 12-month warranty.
Related SpO2 Sensors
Explore more reusable pulse oximetry sensors:
BCI 3043 All Sizes Multi-Y SpO2 Sensor 1.0m, Nellcor DS100A Adult Hard Shell SpO2 Sensor 3.0m, Nellcor D-YS All Sizes Multi-Y SpO2 Sensor 3.0m, Philips M1194B Adult Ear Clip SpO2 Sensor and Masimo 4050 RD SET DCI Adult Clip SpO2 Sensor.
















Reviews
There are no reviews yet.