For Repair Ultrasound & Endoscopic Probes Contact: sales@medicalequipmentsaustralia.com.au
Prices Include GST | Contact Us for International Shipping
, ,

Hamilton Medical 281637 Adult/Pediatric Flow Sensor for C1 C2 C3 T1 & G5 Ventilators (Single Use Box of 10 New)

You Will Receive The Following:

1 x 1 box of 10 × Hamilton Medical 281637 proximal flow sensors (each with 1.88 m tubing)

QTY: 1

Condition: New

Part Number / REF: 281637

Patient Group: Adult / Pediatric

Works With: HAMILTON-C1, C2, C3, C6, T1, MR1, G5 and S1 ventilators

Individually Sealed

EXPRESS SHIPPING

$199.99 Including GST

- +

Have Questions? Contact Us

Shop With Confidence
  • Fast Delivery (2–5 Business Days)
  • No-Risk Money-Back Guarantee
  • No Hassle Refunds
  • 100% Secure Payments
  • 24/7 Customer Support
  • Fully Tracked Shipping
Guaranteed Safe Checkout

Medical Equipments Australia does not provide medical advice, diagnosis, or treatment. Products sold on this website are not intended to replace professional medical advice. Always consult a qualified healthcare professional regarding any medical condition or the use of medical equipment.

The Hamilton 281637 flow sensor is a single-use, proximal (Y-piece) differential-pressure flow sensor for adult and pediatric patients on Hamilton Medical ventilators. Each sensor has 1.88 m of twin measurement tubing with 15M × 15F/22M connectors and measures inspiratory and expiratory flow and airway pressure at the patient airway. This listing is for one box of 10 new sensors, part number (REF) 281637.

Why Choose the Hamilton 281637 Proximal Flow Sensor

  • Measurement at the patient airway: Proximal placement gives the ventilator accurate volume, flow and pressure data for monitoring and synchronisation.
  • Low dead space: Less than 11 ml functional dead space, suited to adult and pediatric tidal volumes.
  • Very low resistance: Under 0.03 cmH2O/(l/min) across the full flow range, adding minimal work of breathing.
  • Wide flow range: 0 to 180 l/min, with short-term flows up to 260 l/min.
  • Single-patient use: Up to 28 days of use per patient (or as your infection-control protocol specifies), which reduces cross-contamination risk and reprocessing workload.
  • Latex-, DEHP- and BPA-free: PSU connectors, PVC tubing and a PET flap.
  • Box of 10: A practical quantity for ICU, emergency and transport ventilation stock.

Key Features of the Hamilton Adult/Pediatric Flow Sensor

Variable-Orifice Differential-Pressure Design

A thin PET flap inside the sensor housing bends in proportion to gas flow. The pressure difference across the flap goes to the ventilator through the twin tubing and is converted into flow and volume readings.

1.88 m Measurement Tubing

The 188 cm twin tubing runs from the patient Y-piece to the ventilator’s flow sensor ports, leaving room to position the breathing circuit at the bedside or during transport.

Standard 15M × 15F/22M Connectors

Standard conical connectors fit between the breathing circuit Y-piece and the airway interface (ETT connector, HMEF or mask).

Individually Sealed

Each sensor comes in its own sealed pouch with a tubing clip, so it can be stocked and opened as needed.

Hamilton 281637 Flow Sensor Specifications

SpecificationDetail
BrandHamilton Medical
Part Number (REF)281637
Product TypeProximal flow sensor, single-patient use
Patient GroupAdult / Pediatric
Tubing Length1.88 m (188 cm)
Connectors15M × 15F/22M
Flow Range0 – 180 l/min (short term 260 l/min)
Dead Space< 11 ml (functional)
Resistance< 0.03 cmH2O/(l/min) over the full flow range
Accuracy±10% or ±10 ml (C1/T1/MR1/C2/C3/C6); ±20% or ±20 ml (G5/S1), whichever is greater
MaterialsPSU connectors, PVC tubing, PET flap
Latex / DEHP / BPAFree of natural rubber latex, DEHP and BPA
WeightApprox. 68 g per sensor (with tubing)
Operating Temperature-20 °C to 50 °C
Operating LifeUp to 28 days, or per hospital infection-control protocol
Quantity10 sensors per box
ConditionNew

Fits These Hamilton Ventilators

  • HAMILTON-C1
  • HAMILTON-C2
  • HAMILTON-C3
  • HAMILTON-C6
  • HAMILTON-T1
  • HAMILTON-MR1
  • HAMILTON-G5
  • HAMILTON-S1

Clinical Use Cases

  • Intensive care units: Invasive and non-invasive ventilation of adult and pediatric patients.
  • Emergency departments: Quick sensor changes between patients on the HAMILTON-C1 and T1.
  • Patient transport: Ground and air transport on the HAMILTON-T1.
  • MRI suites: Ventilation on the HAMILTON-MR1.
  • Stock replenishment: Keeping biomedical and respiratory therapy departments supplied.

How to Use and Replace the Flow Sensor

  • Fit the sensor between the breathing circuit Y-piece and the patient airway, with the tubing facing up to keep condensate out.
  • Connect the blue and clear tubes to the matching flow sensor ports on the ventilator.
  • Run the ventilator’s flow sensor calibration/tightness test after every sensor change.
  • Replace after 28 days, when switching patients, or if the sensor is contaminated, damaged or fails calibration.
  • Single-patient use only. Do not clean, sterilise or reuse.

Frequently Asked Questions

What is the Hamilton 281637 flow sensor used for?

It measures flow, volume and airway pressure at the patient’s Y-piece for adult and pediatric patients on Hamilton Medical ventilators such as the C1, C2, C3, T1 and G5.

How many flow sensors are in a box?

One box has 10 individually sealed single-use sensors.

Is the 281637 flow sensor reusable?

No. It is single-patient use, for up to 28 days or as your infection-control protocol specifies. Do not reprocess it.

Can the 281637 be used on neonates?

No. The 281637 is for adult and pediatric patients. Neonatal ventilation uses a dedicated neonatal flow sensor with lower dead space.

How long is the flow sensor tubing?

The measurement tubing is 1.88 m (188 cm) long.

Do I need to calibrate the sensor after fitting it?

Yes. Run the ventilator’s flow sensor calibration after connecting a new sensor, and whenever the ventilator prompts you to.

Does the Hamilton 281637 contain latex?

No. It contains no natural rubber latex, DEHP or BPA.

Related Hamilton Ventilator Parts & Accessories

For the rest of your Hamilton setup, see the Hamilton C1/C2/C3 396200/01 oxygen sensor, the Hamilton C1/T1 369108 rechargeable battery and the 369106 replacement battery for Hamilton C2/C3. If you need a different flow sensor, see the 155500 disposable flow sensors (box of 10), or browse all ventilators & parts.

Reviews

There are no reviews yet.

Be the first to review “Hamilton Medical 281637 Adult/Pediatric Flow Sensor for C1 C2 C3 T1 & G5 Ventilators (Single Use Box of 10 New)”

Your email address will not be published. Required fields are marked *

Hamilton 281637 adult/pediatric flow sensor box of 10 with sealed sensor and 1.88 m tubingHamilton 281637 adult/pediatric flow sensor box of 10 with sealed sensor and 1.88 m tubingHamilton Medical 281637 Adult/Pediatric Flow Sensor for C1 C2 C3 T1 & G5 Ventilators (Single Use Box of 10 New)
$199.99 Including GST
- +

Have Questions? Contact Us

Shop With Confidence
  • Fast Delivery (2–5 Business Days)
  • No-Risk Money-Back Guarantee
  • No Hassle Refunds
  • 100% Secure Payments
  • 24/7 Customer Support
  • Fully Tracked Shipping
Scroll to Top