For Repair Ultrasound & Endoscopic Probes Contact: sales@medicalequipmentsaustralia.com.au
Prices Include GST | Contact Us for International Shipping

8MHz Ultrasound Vascular Doppler BV520E (BV-520E) Upgrade Handheld Portable Blood Flow Detector For Human

You Will Receive The Following:

1 x 8MHz Ultrasound Vascular Doppler BV520e Upgrade Handheld Portable Blood Flow Detector For Human

QTY: 1

Condition: New

EXPRESS SHIPPING

$699.99 Including GST

- +

Have Questions? Contact Us

Shop With Confidence
  • Fast Delivery (2–5 Business Days)
  • No-Risk Money-Back Guarantee
  • No Hassle Refunds
  • 100% Secure Payments
  • 24/7 Customer Support
  • Fully Tracked Shipping
Guaranteed Safe Checkout

Medical Equipments Australia does not provide medical advice, diagnosis, or treatment. Products sold on this website are not intended to replace professional medical advice. Always consult a qualified healthcare professional regarding any medical condition or the use of medical equipment.

The BV-520E Vascular Doppler is a handheld 8MHz digital ultrasonic blood-flow detector designed for non-invasive assessment of peripheral arterial and venous blood flow. Its 8.0MHz Doppler probe detects vascular blood-flow signals and provides blood-flow velocity measurements, making the compact device suitable for peripheral vascular assessment in clinical and professional healthcare environments.

The BV-520E uses an 8.0MHz ±10% ultrasonic Doppler frequency to detect blood-flow conditions in peripheral vessels. The device can assist trained healthcare professionals in distinguishing arterial and venous flow through characteristic Doppler sounds and evaluating blood-flow velocity.

Its compact design, rechargeable lithium-ion battery, built-in speaker, and 2.4-inch display make the BV-520E digital vascular Doppler convenient for portable examinations.

Key Benefits

  • 8.0MHz Doppler probe for peripheral vascular blood-flow detection
  • Measures blood-flow velocity within a 40–200cm/s range
  • 2.4-inch display for viewing blood-flow information
  • Built-in speaker provides audible Doppler blood-flow signals
  • Smart noise-reduction design for clearer audio output
  • Blood-flow signal intensity display
  • Non-invasive blood-flow velocity assessment
  • Compact and lightweight handheld construction
  • Built-in rechargeable lithium-ion battery
  • Supports AC/DC operation
  • Suitable for professional vascular and peripheral blood-flow examinations

Clear Arterial and Venous Blood-Flow Signals

The BV-520E assists trained professionals in differentiating arterial and venous blood-flow signals by their characteristic acoustic patterns.

Arterial flow generally produces a stronger, rhythmic Doppler sound with cyclical peaks and valleys, while venous flow tends to produce a softer and more continuous sound pattern. The device’s audio output and signal display help the operator evaluate detected vascular signals during examination.

Important: 

The BV-520E is intended for use by appropriately trained healthcare professionals. It should not be used as a substitute for clinical diagnosis or other required diagnostic testing.

Portable Design for Clinical Use

With a physical size of approximately 7 × 13 × 4cm and a product weight of approximately 0.25kg, the BV-520E is designed for convenient handling and transportation.

The integrated rechargeable battery allows the device to be used away from a fixed power source, while the AC/DC power design provides flexible operation and charging.

Designed for Professional Vascular Assessment

The BV-520E can be used in professional healthcare settings where peripheral blood-flow assessment is required, including:

  • Vascular surgery
  • Cardiothoracic surgery
  • Burn and plastic surgery
  • Orthopedic and trauma surgery
  • Microsurgery
  • Functional examination departments
  • Urology and andrology
  • Peripheral vascular assessment

Clinical and Professional Applications

Vascular Surgery

The BV-520E can assist healthcare professionals in evaluating peripheral vascular blood-flow signals when assessing conditions involving limb vessels. It may be used to help identify changes associated with arterial narrowing or obstruction and to monitor peripheral venous blood-flow characteristics.

Cardiothoracic Surgery

The handheld Doppler can assist with locating peripheral blood vessels and evaluating detectable blood-flow signals during relevant clinical procedures.

Burn and Plastic Surgery

The device can be used for peripheral vascular assessment before and after procedures involving tissue or flap transplantation, helping trained professionals evaluate detectable vascular reperfusion signals.

Orthopedic and Trauma Surgery

The BV-520E can assist in checking detectable blood-flow signals following vascular anastomosis procedures involving the limbs.

Microsurgery

For microsurgical procedures involving fingers and toes, the device can be used to assess blood-flow signals and vascular anastomosis conditions before and after surgery.

Urology and Andrology

The BV-520E can be used by qualified professionals to evaluate blood-flow velocity signals from penile arteries as part of appropriate clinical vascular assessment.

Technical Specifications: BV-520E 

SpecificationDetails
ModelBV-520E
Product TypeDigital Ultrasonic Vascular Doppler
Primary FunctionPeripheral Blood-Flow Detection and Velocity Measurement
Ultrasonic Frequency8.0MHz ±10%
Transmitting WaveformSine wave
Average Ultrasonic Power Sound Intensity<20mW/cm²
Speed Measurement Range40–200cm/s
Speed Measurement Error<20% relative error
Display2.4-inch
Audio OutputBuilt-in speaker
Power SupplyAC/DC operation
Input Power<50VA
BatteryBuilt-in rechargeable Li-ion battery
Power IndicatorGreen LED
Charging IndicatorGreen during charging; turns off when fully charged
Product DimensionsApproximately 7 × 13 × 4cm
Product WeightApproximately 0.25kg
Package DimensionsApproximately 20 × 10 × 20cm
Package WeightApproximately 0.75kg

Features At A Glance: BV-520E 

8MHz Ultrasonic Doppler Technology

The 8.0MHz Doppler system is designed for detecting peripheral arterial and venous blood-flow signals.

Blood-Flow Velocity Measurement

The device provides a specified velocity measurement range of 40–200cm/s, with a stated relative measurement error of less than 20%.

Signal Intensity Display

The BV-520E provides a visual indication of blood-flow signal intensity to support professional assessment.

Clear Doppler Audio

The integrated speaker delivers audible Doppler signals, while the noise-reduction function helps improve listening clarity.

Rechargeable Portable Operation

A built-in lithium-ion battery makes the device convenient for mobile examinations and professional use in different clinical areas.

Compact 2.4-Inch Display

The 2.4-inch screen provides a compact interface for displaying relevant blood-flow information.

Who Can Use the BV-520E?

The BV520E 8MHz vascular Doppler is designed for use by trained healthcare professionals who require a portable device for peripheral blood-flow assessment. Its applications can extend across vascular, surgical, orthopedic, microsurgical, plastic surgery, urological, and other relevant clinical departments.

What’s Included?

Each package includes:

  • 1 × BV-520E Vascular Doppler
  • 1 × Power Charger
  • 1 × User Manual

Frequently Asked Questions

What is the BV-520E Vascular Doppler?

The BV520E is a handheld 8MHz digital ultrasonic vascular Doppler designed to detect peripheral arterial and venous blood-flow signals and measure blood-flow velocity.

What frequency does the BV-520E use?

The BV520E uses an 8.0MHz ±10% ultrasonic Doppler frequency for blood-flow detection.

What blood-flow velocity can the BV-520E measure?

The specified blood-flow velocity measurement range is 40–200cm/s.

Does the BV-520E detect both arteries and veins?

Yes. The device is designed to detect peripheral blood-flow signals from both arterial and venous vessels. Different Doppler sound characteristics can assist trained professionals in distinguishing the two.

Is the BV-520E portable?

Yes. The device has a compact handheld design, weighs approximately 0.25kg, and incorporates a rechargeable lithium-ion battery for portable operation.

Does the BV-520E have a display?

Yes. The device features a 2.4-inch display for viewing relevant blood-flow information and signal intensity.

Does the BV-520E have an internal speaker?

Yes. The BV520E includes a built-in speaker for audible Doppler blood-flow signals.

What is included with the BV-520E?

The standard package includes the BV520E vascular Doppler, power charger, and user manual.

What departments can use the BV-520E?

Potential professional applications include vascular surgery, cardiothoracic surgery, burn and plastic surgery, orthopedic trauma surgery, microsurgery, functional examination, urology, and andrology.

Is the BV-520E a diagnostic replacement for other vascular tests?

No. The BV520E is a blood-flow detection and velocity assessment device. Clinical findings should be interpreted by qualified healthcare professionals alongside the patient’s history, examination, and other appropriate diagnostic investigations.

Reviews

There are no reviews yet.

Be the first to review “8MHz Ultrasound Vascular Doppler BV520E (BV-520E) Upgrade Handheld Portable Blood Flow Detector For Human”

Your email address will not be published. Required fields are marked *

BV-520E 8MHz Vascular Doppler Blood Flow DetectorBV-520E 8MHz Vascular Doppler Blood Flow Detector8MHz Ultrasound Vascular Doppler BV520E (BV-520E) Upgrade Handheld Portable Blood Flow Detector For Human
$699.99 Including GST
- +

Have Questions? Contact Us

Shop With Confidence
  • Fast Delivery (2–5 Business Days)
  • No-Risk Money-Back Guarantee
  • No Hassle Refunds
  • 100% Secure Payments
  • 24/7 Customer Support
  • Fully Tracked Shipping
Scroll to Top