This mainstream EtCO2 sensor is engineered for healthcare professionals who require dependable carbon dioxide monitoring during anesthesia, ventilation, emergency care, and critical patient monitoring. Its 14-pin connector ensures seamless fit with supported Nihon Kohden monitoring systems.
Designed with dual-wavelength infrared technology and no moving internal parts, the sensor provides stable readings, low maintenance requirements, and rapid waveform display.
Key Features of the Nihon Kohden ETCO2 Sensor
Accurate Capnography Monitoring
- Measures CO2 concentration with high precision
- Supports real-time respiratory monitoring
- Ideal for adult and pediatric applications
Fast Initialization Time
- Capnogram displayed in under 4 seconds
- Full operating specifications achieved within 2 minutes
Advanced Infrared Technology
- Non-dispersive infrared (NDIR) dual-wavelength system
- No moving parts for improved durability and reliability
Reliable Sample Flow Rate
- Adjustable sample flow rate range: 50–150 ml/min
- Default flow rate: 75 ml/min
- Accuracy: ±20%
Medical-Grade Build Quality
- Latex-free construction for safer patient use
- CE, ISO, ISO13485, and TUV certified
- Durable lightweight design for clinical environments
Benefits of Using This Mainstream ETCO2 Sensor
Enhanced Patient Safety
Continuous EtCO2 monitoring helps clinicians quickly detect respiratory changes, airway issues, and ventilation abnormalities.
Stable and Consistent Readings
The advanced infrared sensing technology ensures accurate CO2 monitoring with minimal signal interruption.
Fits Nihon Kohden Systems
Specifically designed for supported Nihon Kohden patient monitors with a 14-pin interface.
Suitable for Multiple Medical Settings
Commonly used in:
- Intensive Care Units (ICU)
- Operating Rooms
- Emergency Departments
- Ambulance and Transport Monitoring
- Recovery Rooms
- Ventilator Monitoring Applications
Technical Specifications
| Specification | Details |
| Product Name | Nihon Kohden Mainstream EtCO2 Sensor 14 Pins |
| Fitment | Nihon Kohden Monitors |
| Category | EtCO2 Sensor |
| Sensor Type | Mainstream Capnography Sensor |
| Connector Type | 14 Pins |
| Principle of Operation | Non-dispersive Infrared (NDIR), Dual Wavelength |
| CO2 Measurement Range | 0–114 mmHg |
| CO2 Percentage Range | 0–15% |
| kPa Measurement Range | 0–15.2 kPa |
| Sample Flow Rate | 50–150 ml/min |
| Default Flow Rate | 75 ml/min |
| Flow Rate Accuracy | ±20% |
| Initialization Time | Capnogram in <4 seconds |
| Full Specification Time | Within 2 minutes at 25°C |
| Latex-Free | Yes |
| Sterile | No |
| Certifications | CE, ISO, ISO13485, TUV |
| Packaging Type | Bag |
| Package Included | 1 x ETCO2 Sensor |
| Weight | 0.8 lb |
| Warranty | 3 Months |
| Vendor | Medical Equipment Australia |
Why Choose This Nihon Kohden EtCO2 Sensor?
Dependable Clinical Performance
This sensor is manufactured for continuous respiratory monitoring in demanding healthcare environments.
Easy Integration
The 14-pin configuration allows quick installation with supported Nihon Kohden monitoring systems.
Durable Medical Design
With no moving parts inside the sensor, maintenance requirements are minimised while operational lifespan is improved.
Applications of the Nihon Kohden Mainstream CO2 Sensor
Surgical Monitoring
Used during anesthesia procedures to monitor patient ventilation in real time.
ICU Respiratory Care
Supports continuous capnography monitoring for critically ill patients.
Emergency and Transport Monitoring
Provides rapid respiratory status assessment in ambulances and emergency response environments.
Ventilator Monitoring
Helps clinicians monitor ventilation effectiveness and detect airway complications.
What’s Included in the Package?
- 1 × Nihon Kohden Mainstream EtCO2 Sensor (14 Pins)
Frequently Asked Questions
What is a Nihon Kohden Mainstream EtCO2 Sensor used for?
This sensor is used to monitor end-tidal carbon dioxide (EtCO2) levels and patient respiratory status during medical procedures and critical care monitoring.
Does this ETCO2 sensor fit all Nihon Kohden monitors?
It is designed for supported Nihon Kohden patient monitors that support a 14-pin mainstream EtCO2 connection.
What technology does this capnography sensor use?
The sensor uses non-dispersive infrared (NDIR) dual-wavelength technology for accurate CO2 measurement.
How quickly does the sensor display readings?
The capnogram appears in less than 4 seconds, with full operating specifications reached within approximately 2 minutes.
What is the CO2 measurement range?
The sensor measures CO2 from 0 to 114 mmHg, equivalent to 0–15% or 0–15.2 kPa.
Is the Nihon Kohden EtCO2 sensor latex-free?
Yes, the sensor is latex-free, making it safer for sensitive clinical environments.
Can this sensor be used in ICU and operating rooms?
Yes, it is commonly used in ICUs, operating theaters, emergency departments, and ventilator monitoring applications.
What certifications does this ETCO2 sensor have?
The sensor is certified with CE, ISO, ISO13485, and TUV standards.
What is included with the purchase?
The package includes one Nihon Kohden Mainstream EtCO2 Sensor with a 14-pin connector.
Does this ETCO2 sensor come with a warranty?
Yes, the product includes a 3-month warranty.
Order the Nihon Kohden Mainstream EtCO2 Sensor 14 Pins Today
Upgrade your patient monitoring system with a reliable and accurate mainstream EtCO2 sensor designed for supported Nihon Kohden monitors. Ideal for hospitals, clinics, emergency care, and respiratory monitoring applications.