The Nellcor Finger Clip SpO2 Sensor Non-OxiMax (3.2 ft, 7-pin connector) is a medical-grade adult pulse oximetry sensor designed to measure blood oxygen saturation (SpO2) and pulse rate accurately when connected to supported Nellcor patient monitors. It features a durable TPU cable, adult finger clip design, and a 7-pin D-Sub connector for reliable clinical use.
Key Features & Benefits
Reliable Clinical Monitoring
- Provides accurate SpO2 and pulse rate readings for adult patients
- Designed for consistent performance in hospital and clinical environments
Wide Fits These Models
- Fits:
- NPB 20, NPB 40
- NPB 75, NPB 180, NPB 185
- NPB 190, NPB 195
- NPB 3900, NPB 4000
Durable Medical-Grade Construction
- TPU jacket cable ensures flexibility and long service life
- Resistant to wear, bending, and repeated clinical use
Comfortable Adult Finger Clip Design
- Ergonomic clip ensures stable placement on the finger
- Suitable for continuous and spot-check monitoring
High Accuracy Performance
- SpO2 accuracy: ±1% to ±3% depending on range
- Pulse rate accuracy: ±2 BPM
- Supports reliable readings even in demanding environments
Certified Safety Standards
- Suitable for professional healthcare environments
Technical Specifications
- Type: Finger Clip SpO2 Sensor
- Technology: Non-OxiMax
- Patient Type: Adult (>88 lb)
- Cable Length: 3.2 ft
- Cable Material: TPU Jacket
- Connector: Male 7-Pin D-Sub
- Cable Colour: Grey
Performance Specifications
| Parameter | Specification |
| SpO2 Range | 50% – 100% |
| SpO2 Accuracy | 85–100%: ±1% / 70–84%: ±2% / 50–69%: ±3% |
| Pulse Rate Range | 25 – 250 BPM |
| Pulse Rate Accuracy | ±2 BPM |
| Operating Temperature | 32°F to +104°F |
| Storage Temperature | 23°F to 104°F |
| Humidity | 0% – 80% (non-condensing) |
| Altitude Pressure | 86 kPa – 106 kPa |
Compliance & Packaging
- Packaging Type: Protective bag
- Included: 1 × Adult Finger Clip SpO2 Sensor
Applications & Use Cases
Clinical & Hospital Use
- Patient monitoring in ICUs and general wards
- Continuous oxygen saturation tracking during treatment
Emergency Care
- Rapid assessment of oxygen levels in emergency situations
- Portable monitoring in ambulances and field care
Diagnostic Use
- Routine vital sign monitoring in clinics
- Pre- and post-operative patient assessment
Product Advantages
- Stable signal acquisition for dependable readings
- Lightweight and flexible cable for ease of movement
- Fits multiple Nellcor monitor models
- Built for long-term clinical reliability
- Designed for adult patients requiring consistent monitoring
Frequently Asked Questions
What devices is this SpO2 sensor fits?
It fits Nellcor monitors including NPB 20, NPB 40, NPB 75, NPB 180, NPB 185, NPB 190, NPB 195, NPB 3900, and NPB 4000.
Is this sensor suitable for adult patients only?
Yes, this model is designed specifically for adult patients weighing over 88 lbs.
What type of connector does it use?
It uses a male 7-pin D-Sub connector for secure fit with supported devices.
What is the accuracy of this SpO2 sensor?
SpO2 accuracy ranges from ±1% to ±3% depending on oxygen saturation levels, and pulse rate accuracy is ±2 BPM.
Is this sensor reusable?
Yes, it is designed for reusable clinical use with proper cleaning and handling.
Does it support continuous monitoring?
Yes, it is suitable for both continuous and spot-check patient monitoring in clinical environments.