The Dräger WaterLock 2 (part number 6872130) is a water trap for Dräger sidestream gas monitoring that stops water, secretions and microbes from reaching the multi-gas sensor.
It uses two hydrophobic 0.2 µm PTFE membranes plus self-sealing safety filters, can be emptied with a standard syringe, and is rated for up to four weeks of use per unit. This box holds 12 units, which Dräger describes as roughly a one-year supply for a single workstation.
Why Choose the WaterLock 2 Water Trap
- Protects the gas analyser: Keeps condensate out of the multi-gas sensor, which helps avoid costly sensor repairs and downtime.
- Stable, accurate readings: Supports reliable CO₂, O₂ and anaesthetic agent readings, including during low-flow and minimal-flow anaesthesia when humidity in the sample gas is high.
- Infection control: The membrane barrier helps stop bacteria and germs entering the gas measurement system.
- Clear warning when blocked: The self-sealing filters turn blue when they are occluded, so staff know it is time to replace the water trap.
- Long service interval: Up to four weeks of use per trap, with the option to empty and continue during that period.
Key Features of the Dräger 6872130 Water Trap
Twin Hydrophobic PTFE Membranes
Two microporous PTFE membranes with 0.2 µm pores let sample gas pass while holding back liquid water and particles.
Self-Sealing Secondary Filters
A second protective stage seals itself if liquid gets past the membranes, stopping water from moving further into the monitor.
Syringe-Emptiable Reservoir
Collected fluid can be drawn off with a standard syringe, so the trap can stay in use for its full service life.
Optimised Housing Geometry
The housing is shaped for fast gas response and efficient drainage, which helps keep the capnography waveform accurate.
WaterLock 2 Specifications
| Specification | Details |
|---|---|
| Product | WaterLock 2 water trap |
| Brand (printed on product) | Dräger |
| Part Number | 6872130 |
| Cross-Reference | 6870567 (earlier part number) |
| Pack Quantity | 12 pieces per box |
| Membranes | 2 × hydrophobic microporous PTFE, 0.2 µm pore size |
| Secondary Protection | Self-sealing filters (turn blue when occluded) |
| Service Life | Up to 4 weeks per water trap |
| Emptying | With a standard syringe |
| Application | Sidestream multi-gas / CO₂ monitoring |
| Certification | CE, ISO |
| Unit Weight | Approx. 0.09 kg |
| Package Size | 20 × 10 × 10 cm |
| Condition | New |
Works With These Dräger Systems
- Dräger Apollo anaesthesia workstation
- Dräger Julian anaesthesia workstation
- Dräger Fabius OS, Fabius Tiro, Fabius Tiro M and Fabius MRI
- Dräger Scio multi-gas modules
- Dräger Vamos anaesthetic gas monitor
- Dräger Infinity Delta patient monitors (with gas module)
Note: Infinity ID-enabled workstations use a different part, the Infinity ID WaterLock 2 (6872020). Please check the part number on your current water trap before ordering.
Common Uses
- Operating theatres running Dräger anaesthesia workstations
- Low-flow and minimal-flow anaesthesia with high sample humidity
- ICU and recovery areas using Dräger multi-gas monitoring
- Biomedical engineering departments stocking planned-maintenance consumables
How to Replace the WaterLock 2
- Pull the used WaterLock 2 out of its holder on the gas module.
- Push the new water trap in until it clicks into place.
- Connect the gas sampling line and check the monitor shows normal readings.
- Empty the reservoir with a syringe as needed and replace the trap after four weeks or when the filters turn blue.
Frequently Asked Questions
What is the Dräger 6872130?
6872130 is the Dräger part number for a box of 12 WaterLock 2 water traps, used to protect the multi-gas sensor in Dräger anaesthesia workstations and gas monitors.
How long does a WaterLock 2 last?
Each WaterLock 2 can be used for up to four weeks. It can be emptied with a syringe during that time.
How do I know when the water trap needs replacing?
The self-sealing filters turn blue when they become blocked. Replace the trap at that point or after four weeks, whichever comes first.
Is 6872130 the same as 6872020?
No. 6872020 is the Infinity ID WaterLock 2 for Infinity ID-enabled devices. 6872130 is the standard WaterLock 2.
What part number did 6872130 replace?
6872130 supersedes part number 6870567.
How many water traps come in one box?
One box contains 12 WaterLock 2 water traps.