MX01049 O2 Sensor Oxytrace For Dräger Savina Savina300 NEW And Original

You Will Receive The Following:

1 x MX01049 O2 sensor Oxytrace for Dräger Savina Savina300 NEW and Original

QTY: 1

Condition: New & Original

EXPRESS SHIPPING

$350.00 Including GST

- +
Guaranteed Safe Checkout

Medical Equipments Australia does not provide medical advice, diagnosis, or treatment. Products sold on this website are not intended to replace professional medical advice. Always consult a qualified healthcare professional regarding any medical condition or the use of medical equipment.

  • Fast Australia Wide Delivery (1 to 7 days) Depending On Location
  • No-Risk Money Back Guarantee!
  • No Hassle Refunds
  • Secure Payments
  • 24/7 Customer Support

The mx01049 oxygen sensor OxyTrace VE is a genuine replacement oxygen cell engineered specifically for compatibility with Savina and Savina 300 ventilators from Dräger. 

Designed to deliver precise inspiratory and expiratory oxygen concentration measurements, this original oxygen sensor ensures optimal performance in critical care ventilation environments.

In modern respiratory therapy and anesthesia delivery systems, accurate oxygen monitoring is not optional, it is clinically essential. The MX01049 OxyTrace oxygen sensor plays a central role in maintaining safe oxygen delivery, supporting clinicians in intensive care units (ICU), emergency departments, surgical suites, and long-term care facilities.

This product is supplied new and original, offering hospital-grade reliability, factory-calibrated accuracy, and full compatibility with Dräger Savina ventilator systems.

Overview: MX01049 OxyTrace VE Oxygen Sensor

The Dräger OXY Trace VE MX01049 oxygen sensor is designed for:

  • Continuous FiO₂ (fraction of inspired oxygen) monitoring
  • Inspiratory and expiratory oxygen concentration measurement
  • Integration within Savina & Savina 300 ventilators
  • Clinical-grade accuracy and long-term stability

As a galvanic oxygen cell, this sensor generates a millivolt output proportional to oxygen concentration. The ventilator converts this signal into a precise oxygen percentage reading, ensuring consistent respiratory support.

Why the Original Dräger MX01049 O2 Sensor Matters

When replacing a ventilator oxygen sensor, using a genuine OEM component is critical.

The original OxyTrace VE sensor:

  • Is factory-tested for Savina series compatibility
  • Meets national and international medical standards
  • Maintains calibrated signal output range (10–14 mV)
  • Ensures proper ventilator alarm functionality
  • Reduces calibration drift and false readings

Non-original sensors may cause:

  • Inaccurate FiO₂ readings
  • Ventilator calibration errors
  • Increased maintenance costs
  • Risk to patient safety

The original MX01049 oxygen cell eliminates these risks by maintaining full system integration integrity.

Technical Specifications: Dräger MX01049 Oxygen Cell

Below are the detailed technical parameters of the OxyTrace VE oxygen sensor:

Measurement Performance

  • Measuring Range: 0–100% O₂
  • Accuracy: ±2% of full scale
  • Linearity: ±2% of full scale
  • Signal Output: 10–14 mV
  • Response Time (T90): 13 seconds

This performance profile ensures rapid detection of oxygen concentration changes during ventilation cycles.

Environmental & Operating Conditions

  • Operating Temperature: 0°C to 40°C
  • Recommended Storage Temperature: 0°C to 25°C
  • Humidity Range: 0–99% RH (non-condensing)
  • Temperature Coefficient: Compensated

The temperature-compensated design allows stable readings across ICU operating conditions.

Durability & Lifecycle

  • Expected Life: Up to 60 months (typical usage conditions)
  • Warranty: 18 months
  • Electrical Connector: SLI type

The long operational lifespan reduces replacement frequency and lowers total cost of ownership for healthcare facilities.

Compatibility: Designed for Savina Ventilator Systems

The MX01049 OxyTrace VE oxygen sensor is fully compatible with:

  • Savina ventilator
  • Savina 300 ventilator

These ventilators are widely used in critical care ventilation, neonatal respiratory support, and emergency respiratory therapy. The OxyTrace VE sensor integrates seamlessly without requiring hardware modification.

Functional Role of the OxyTrace VE Oxygen Sensor

1. Inspiratory Oxygen Monitoring

Measures oxygen concentration delivered to the patient during inhalation.

2. Expiratory Oxygen Verification

Ensures accurate oxygen monitoring during exhalation cycles.

3. Alarm Accuracy

Maintains ventilator alarm thresholds when oxygen concentration deviates from set parameters.

4. Clinical Decision Support

Provides reliable data for respiratory therapists and intensivists.

Advantages of the Genuine MX01049 Oxygen Sensor

High Precision Measurement

±2% full-scale accuracy ensures compliance with clinical ventilation standards.

Fast Response Time

13-second T90 response enables quick adjustment detection.

Stable Millivolt Output

10–14mV signal output ensures proper ventilator interface reading.

Extended Shelf Life

Up to 60 months expected operational life under recommended conditions.

Temperature Compensation

Maintains consistent readings across ICU environmental variations.

Medical-Grade Construction

Manufactured according to strict medical device compliance standards.

Clinical Applications

The OxyTrace VE oxygen sensor is used in:

  • Intensive Care Units (ICU)
  • Emergency Rooms
  • Post-Anesthesia Care Units
  • Surgical Operating Theaters
  • Respiratory Therapy Departments
  • Long-term Ventilation Facilities

Wherever precise oxygen therapy is required, the MX01049 sensor ensures reliable oxygen concentration monitoring.

Installation & Replacement Guidance

Replacing the Savina oxygen sensor is straightforward:

  1. Turn off the ventilator system.
  2. Remove expired oxygen cells.
  3. Install new MX01049 OxyTrace VE sensor.
  4. Allow system calibration cycle.
  5. Verify oxygen concentration readings.

Always follow the manufacturer’s ventilator service manual during replacement.

Storage Recommendations

To maintain maximum lifespan:

  • Store between 0°C and 25°C
  • Avoid condensation exposure
  • Keep sealed until installation
  • Do not expose to extreme humidity

Proper storage ensures sensor electrolyte stability and consistent output voltage.

OEM Quality Assurance

The original Dräger OXY Trace VE MX01049 sensor undergoes:

  • Performance testing
  • Electrical calibration verification
  • Environmental stress validation
  • Compatibility testing with Savina systems

This ensures full regulatory compliance and safe integration into medical ventilation equipment.

Performance Reliability in Critical Care

In respiratory devices, oxygen concentration accuracy directly impacts:

  • Hypoxia prevention
  • Hyperoxia control
  • Ventilator alarm reliability
  • Patient safety

The MX01049 oxygen cell supports safe ventilation management by maintaining consistent oxygen measurement throughout treatment cycles.

Frequently Asked Questions

What is the part number of this oxygen sensor?

The official part number is MX01049, also referred to as OxyTrace VE oxygen sensor.

Is this sensor original and genuine?

Yes. This is a new and original OXY Trace VE oxygen sensor designed specifically for Savina and Savina 300 ventilators.

Which ventilators is the MX01049 compatible with?

It is compatible with Savina and Savina 300 ventilator systems.

What type of oxygen sensing technology is used?

It uses galvanic oxygen cell technology that generates a millivolt output proportional to oxygen concentration.

What is the measuring range?

The sensor measures oxygen concentration from 0% to 100% O₂.

How accurate is the OxyTrace VE sensor?

It provides ±2% full-scale accuracy with ±2% linearity.

What is the response time?

The T90 response time is approximately 13 seconds.

What is the expected lifespan?

Under recommended conditions, the expected operational life is up to 60 months.

What is the output signal range?

The output voltage range is 10–14 mV.

What environmental conditions does it support?

It operates between 0–40°C with non-condensing humidity up to 99% RH.

Why Healthcare Facilities Choose the Original MX01049

Hospitals and biomedical departments prioritize:

  • Patient safety
  • Accurate oxygen therapy
  • Equipment reliability
  • Regulatory compliance

The Dräger Savina OxyTrace MX01049 oxygen sensor delivers dependable oxygen concentration monitoring, supporting both clinical precision and long-term cost efficiency.

Order the Genuine MX01049 O2 Sensor Today

Ensure optimal ventilator performance with the original OxyTrace VE oxygen cell. Designed specifically for Savina ventilators, this high-precision oxygen sensor supports safe respiratory therapy and consistent clinical outcomes.

For healthcare providers, biomedical engineers, and medical equipment distributors, the MX01049 oxygen sensor represents reliability, compatibility, and performance you can trust.

Reviews

There are no reviews yet.

Be the first to review “MX01049 O2 Sensor Oxytrace For Dräger Savina Savina300 NEW And Original”

Your email address will not be published. Required fields are marked *

Shopping Cart
Dräger Savina mx01049 oxygen sensor OxyTrace VE original O2 cell for Savina and Savina 300 ventilatorMX01049 O2 Sensor Oxytrace For Dräger Savina Savina300 NEW And Original
$350.00 Including GST
- +
Scroll to Top