The mx01049 oxygen sensor OxyTrace VE is a genuine replacement oxygen cell engineered specifically for compatibility with Savina and Savina 300 ventilators from Dräger.
Designed to deliver precise inspiratory and expiratory oxygen concentration measurements, this original oxygen sensor ensures optimal performance in critical care ventilation environments.
In modern respiratory therapy and anesthesia delivery systems, accurate oxygen monitoring is not optional, it is clinically essential. The MX01049 OxyTrace oxygen sensor plays a central role in maintaining safe oxygen delivery, supporting clinicians in intensive care units (ICU), emergency departments, surgical suites, and long-term care facilities.
This product is supplied new and original, offering hospital-grade reliability, factory-calibrated accuracy, and full compatibility with Dräger Savina ventilator systems.
Overview: MX01049 OxyTrace VE Oxygen Sensor
The Dräger OXY Trace VE MX01049 oxygen sensor is designed for:
- Continuous FiO₂ (fraction of inspired oxygen) monitoring
- Inspiratory and expiratory oxygen concentration measurement
- Integration within Savina & Savina 300 ventilators
- Clinical-grade accuracy and long-term stability
As a galvanic oxygen cell, this sensor generates a millivolt output proportional to oxygen concentration. The ventilator converts this signal into a precise oxygen percentage reading, ensuring consistent respiratory support.
Why the Original Dräger MX01049 O2 Sensor Matters
When replacing a ventilator oxygen sensor, using a genuine OEM component is critical.
The original OxyTrace VE sensor:
- Is factory-tested for Savina series compatibility
- Meets national and international medical standards
- Maintains calibrated signal output range (10–14 mV)
- Ensures proper ventilator alarm functionality
- Reduces calibration drift and false readings
Non-original sensors may cause:
- Inaccurate FiO₂ readings
- Ventilator calibration errors
- Increased maintenance costs
- Risk to patient safety
The original MX01049 oxygen cell eliminates these risks by maintaining full system integration integrity.
Technical Specifications: Dräger MX01049 Oxygen Cell
Below are the detailed technical parameters of the OxyTrace VE oxygen sensor:
Measurement Performance
- Measuring Range: 0–100% O₂
- Accuracy: ±2% of full scale
- Linearity: ±2% of full scale
- Signal Output: 10–14 mV
- Response Time (T90): 13 seconds
This performance profile ensures rapid detection of oxygen concentration changes during ventilation cycles.
Environmental & Operating Conditions
- Operating Temperature: 0°C to 40°C
- Recommended Storage Temperature: 0°C to 25°C
- Humidity Range: 0–99% RH (non-condensing)
- Temperature Coefficient: Compensated
The temperature-compensated design allows stable readings across ICU operating conditions.
Durability & Lifecycle
- Expected Life: Up to 60 months (typical usage conditions)
- Warranty: 18 months
- Electrical Connector: SLI type
The long operational lifespan reduces replacement frequency and lowers total cost of ownership for healthcare facilities.
Compatibility: Designed for Savina Ventilator Systems
The MX01049 OxyTrace VE oxygen sensor is fully compatible with:
- Savina ventilator
- Savina 300 ventilator
These ventilators are widely used in critical care ventilation, neonatal respiratory support, and emergency respiratory therapy. The OxyTrace VE sensor integrates seamlessly without requiring hardware modification.
Functional Role of the OxyTrace VE Oxygen Sensor
1. Inspiratory Oxygen Monitoring
Measures oxygen concentration delivered to the patient during inhalation.
2. Expiratory Oxygen Verification
Ensures accurate oxygen monitoring during exhalation cycles.
3. Alarm Accuracy
Maintains ventilator alarm thresholds when oxygen concentration deviates from set parameters.
4. Clinical Decision Support
Provides reliable data for respiratory therapists and intensivists.
Advantages of the Genuine MX01049 Oxygen Sensor
High Precision Measurement
±2% full-scale accuracy ensures compliance with clinical ventilation standards.
Fast Response Time
13-second T90 response enables quick adjustment detection.
Stable Millivolt Output
10–14mV signal output ensures proper ventilator interface reading.
Extended Shelf Life
Up to 60 months expected operational life under recommended conditions.
Temperature Compensation
Maintains consistent readings across ICU environmental variations.
Medical-Grade Construction
Manufactured according to strict medical device compliance standards.
Clinical Applications
The OxyTrace VE oxygen sensor is used in:
- Intensive Care Units (ICU)
- Emergency Rooms
- Post-Anesthesia Care Units
- Surgical Operating Theaters
- Respiratory Therapy Departments
- Long-term Ventilation Facilities
Wherever precise oxygen therapy is required, the MX01049 sensor ensures reliable oxygen concentration monitoring.
Installation & Replacement Guidance
Replacing the Savina oxygen sensor is straightforward:
- Turn off the ventilator system.
- Remove expired oxygen cells.
- Install new MX01049 OxyTrace VE sensor.
- Allow system calibration cycle.
- Verify oxygen concentration readings.
Always follow the manufacturer’s ventilator service manual during replacement.
Storage Recommendations
To maintain maximum lifespan:
- Store between 0°C and 25°C
- Avoid condensation exposure
- Keep sealed until installation
- Do not expose to extreme humidity
Proper storage ensures sensor electrolyte stability and consistent output voltage.
OEM Quality Assurance
The original Dräger OXY Trace VE MX01049 sensor undergoes:
- Performance testing
- Electrical calibration verification
- Environmental stress validation
- Compatibility testing with Savina systems
This ensures full regulatory compliance and safe integration into medical ventilation equipment.
Performance Reliability in Critical Care
In respiratory devices, oxygen concentration accuracy directly impacts:
- Hypoxia prevention
- Hyperoxia control
- Ventilator alarm reliability
- Patient safety
The MX01049 oxygen cell supports safe ventilation management by maintaining consistent oxygen measurement throughout treatment cycles.
Frequently Asked Questions
What is the part number of this oxygen sensor?
The official part number is MX01049, also referred to as OxyTrace VE oxygen sensor.
Is this sensor original and genuine?
Yes. This is a new and original OXY Trace VE oxygen sensor designed specifically for Savina and Savina 300 ventilators.
Which ventilators is the MX01049 compatible with?
It is compatible with Savina and Savina 300 ventilator systems.
What type of oxygen sensing technology is used?
It uses galvanic oxygen cell technology that generates a millivolt output proportional to oxygen concentration.
What is the measuring range?
The sensor measures oxygen concentration from 0% to 100% O₂.
How accurate is the OxyTrace VE sensor?
It provides ±2% full-scale accuracy with ±2% linearity.
What is the response time?
The T90 response time is approximately 13 seconds.
What is the expected lifespan?
Under recommended conditions, the expected operational life is up to 60 months.
What is the output signal range?
The output voltage range is 10–14 mV.
What environmental conditions does it support?
It operates between 0–40°C with non-condensing humidity up to 99% RH.
Why Healthcare Facilities Choose the Original MX01049
Hospitals and biomedical departments prioritize:
- Patient safety
- Accurate oxygen therapy
- Equipment reliability
- Regulatory compliance
The Dräger Savina OxyTrace MX01049 oxygen sensor delivers dependable oxygen concentration monitoring, supporting both clinical precision and long-term cost efficiency.
Order the Genuine MX01049 O2 Sensor Today
Ensure optimal ventilator performance with the original OxyTrace VE oxygen cell. Designed specifically for Savina ventilators, this high-precision oxygen sensor supports safe respiratory therapy and consistent clinical outcomes.
For healthcare providers, biomedical engineers, and medical equipment distributors, the MX01049 oxygen sensor represents reliability, compatibility, and performance you can trust.

















Reviews
There are no reviews yet.