,

Boston Scientific H74939171040270 Mustang OVER-THE-WIRE 5F 4.0mm x 20mm x 75cm PTA Balloon Dilatation Catheter

You Will Receive The Following:

1 x Boston Scientific H74939171040270 Mustang OVER-THE-WIRE 5F 4.0mm x 20mm x 75cm PTA Balloon Dilatation Catheter

QTY: 1

Condition: New & Original

EXPRESS SHIPPING

$499.99 Including GST

- +
Guaranteed Safe Checkout

Medical Equipments Australia does not provide medical advice, diagnosis, or treatment. Products sold on this website are not intended to replace professional medical advice. Always consult a qualified healthcare professional regarding any medical condition or the use of medical equipment.

  • Fast Australia Wide Delivery (1 to 7 days) Depending On Location
  • No-Risk Money Back Guarantee!
  • No Hassle Refunds
  • Secure Payments
  • 24/7 Customer Support

The Boston Scientific Mustang™ H74939171040270 OVER-THE-WIRE PTA Balloon Dilatation Catheter is engineered to deliver dependable performance in peripheral vascular interventions requiring controlled, high-pressure dilatation. 

Designed for physicians performing percutaneous transluminal angioplasty (PTA), this catheter combines advanced balloon material technology, optimal shaft performance, and precise positioning features to support efficient treatment of obstructive vascular lesions.

This configuration features a 4.0 mm balloon diameter, 20 mm balloon length, and 75 cm catheter shaft, making it suitable for treating a wide range of peripheral arterial lesions while maintaining compatibility with standard clinical equipment setups. With its 5F sheath compatibility and 0.035″ guidewire support, the device integrates smoothly into existing intervention workflows.

Manufactured under stringent medical device standards and supplied in intact, original packaging, the catheter ensures sterility and performance consistency required in clinical settings.

Product Identification

  • Brand: Boston Scientific
  • Product Line: Mustang™ PTA Balloon Dilatation Catheter
  • Model / Part Number: H74939171040270
  • SKU: BOST-H74939171040270
  • Catheter Type: Over-the-Wire (OTW) Balloon Dilatation Catheter
  • French Size Compatibility: 5F introducer sheath or larger
  • Guidewire Compatibility: ≤ 0.035″ (0.89 mm)
  • Balloon Size: 4.0 mm × 20 mm
  • Shaft Length: 75 cm
  • Rated Burst Pressure: Up to 24 atm
  • Use Type: Single-use, sterile medical device

Designed for Reliable Peripheral Angioplasty Performance

Peripheral vascular disease treatments demand devices capable of navigating challenging vessel anatomy while delivering consistent dilatation force. The Mustang™ balloon catheter is specifically designed for peripheral PTA procedures, addressing lesions found in:

  • Iliac arteries
  • Femoral arteries
  • Popliteal arteries
  • Tibial and peroneal vessels
  • Subclavian arteries
  • Renal arteries
  • Native and synthetic AV dialysis fistulae
  • Post-stent deployment dilatation procedures

The catheter enables physicians to safely expand narrowed vessels, restore blood flow, and optimize stent placement when required.

Advanced Balloon Material Technology

One of the most notable features of the Mustang™ system is the NyBax™ balloon material, a proprietary co-extrusion of nylon and Pebax®. This material combination provides several procedural advantages:

High Pressure Capability

The balloon maintains structural integrity even at elevated pressures, enabling treatment of resistant or fibrotic lesions while minimizing the risk of balloon rupture.

Excellent Rewrapping Performance

After inflation, the balloon folds efficiently, simplifying catheter withdrawal and reducing friction within the sheath and vessel.

Controlled Compliance

The balloon delivers predictable expansion characteristics, allowing clinicians to achieve precise vessel sizing during angioplasty.

This balance of strength and flexibility is essential in modern PTA balloon catheter systems.

Enhanced Deliverability and Navigation

Peripheral interventions often involve tortuous or calcified vascular pathways. The Mustang™ catheter is engineered for smooth device advancement through challenging anatomy.

Low Entry Profile

The catheter’s lesion crossing profile is only slightly larger than the guidewire, enabling efficient lesion access and reducing resistance at stenotic segments.

Hydrophilic Coating

The shaft coating minimizes friction, improving catheter trackability through vascular structures and sheath systems.

Smooth Pushability and Torque Response

The shaft construction ensures controlled movement, supporting accurate positioning during intervention.

These characteristics collectively reduce procedure time and enhance procedural success rates.

Accurate Positioning Under Fluoroscopy

Precise balloon placement is critical in angioplasty procedures. The Mustang™ catheter includes radiopaque platinum-iridium markers positioned to indicate balloon working length clearly under fluoroscopic imaging.

This enables physicians to:

  • Accurately center the balloon within the lesion
  • Reduce geographic miss
  • Improve treatment precision
  • Optimize stent post-dilatation

Improved visibility contributes to safer and more efficient procedures.

Compatibility with Standard Clinical Equipment

The catheter integrates seamlessly with commonly used vascular intervention equipment:

  • Compatible with 0.035″ guidewires, widely used in peripheral procedures
  • Works with 5F or larger introducer sheaths
  • Suitable for standard inflation devices
  • Supports use across multiple vascular access strategies

This compatibility simplifies adoption and reduces the need for workflow modifications.

Clinical Applications

The Mustang™ PTA balloon dilatation catheter is indicated for use in multiple peripheral vascular treatments, including:

Peripheral Artery Disease Treatment

Enables vessel widening in stenosed peripheral arteries to restore circulation.

Dialysis Access Maintenance

Used in treatment of obstructive lesions in AV fistulae and grafts to maintain dialysis access functionality.

Stent Optimization

Ideal for post-deployment balloon expansion of both balloon-expandable and self-expanding stents.

Multi-Segment Lesion Treatment

Suitable for treating short-segment lesions requiring controlled dilatation.

Sterility and Packaging Assurance

Each catheter is supplied in original manufacturer packaging, ensuring:

  • Sterility at point of use
  • Protection during transport and storage
  • Device integrity until procedure time

Packaging integrity is crucial in maintaining compliance with hospital and clinical sterilization protocols.

Why Healthcare Facilities Choose Mustang™ PTA Catheters

Medical facilities and interventional specialists frequently select Mustang™ catheters because they offer:

  • Reliable balloon strength for difficult lesions
  • Excellent deliverability across vessel anatomy
  • Smooth retraction after inflation
  • Consistent procedural outcomes
  • Trusted Boston Scientific engineering quality

The device balances performance, safety, and procedural efficiency.

Performance Benefits in Real Procedures

Clinicians often encounter situations requiring rapid yet precise vessel dilatation. Mustang™ catheters help achieve:

  • Improved lesion crossing success
  • Reduced need for catheter exchanges
  • Enhanced vessel expansion control
  • Improved workflow efficiency
  • Reduced procedural complications

These advantages translate into smoother interventions and improved patient outcomes.

Key Advantages Summary

✔ High-pressure balloon capability (24 atm)
✔ Low-profile entry design
✔ Smooth hydrophilic-coated shaft
✔ Strong deliverability performance
✔ Excellent balloon rewrap behavior
✔ Accurate radiopaque markers
✔ Compatible with standard vascular systems
✔ Suitable for multiple peripheral applications

Handling and Usage Considerations

This catheter is intended for use by trained healthcare professionals only. Standard precautions apply, including:

  • Careful handling in calcified lesions
  • Proper sheath size selection
  • Controlled balloon inflation practices
  • Use in accordance with institutional protocols

The device is designed for single-use only.

Frequently Asked Questions

What procedures is the Mustang™ PTA balloon catheter mainly used for?

It is primarily used in peripheral angioplasty procedures to open narrowed or blocked arteries and improve blood flow.

Is the catheter compatible with common guidewires?

Yes, it supports guidewires up to 0.035 inches, which are commonly used in peripheral vascular interventions.

What sheath size is required?

A minimum introducer sheath size of 5F is recommended.

Can it be used for stent post-dilatation?

Yes, it is suitable for post-dilatation of both balloon-expandable and self-expanding stents.

Does the balloon maintain performance at high pressures?

Yes, the balloon material supports inflation pressures up to 24 atm for effective lesion treatment.

How does the catheter improve deliverability?

The hydrophilic coating and optimized shaft design reduce friction and improve navigation through complex anatomy.

Is the device reusable?

No, it is a sterile, single-use medical device.

Does it provide clear imaging visibility?

Yes, platinum-iridium markers allow precise balloon placement under fluoroscopy.

Can it be used in dialysis access procedures?

Yes, it is indicated for treatment of obstructive lesions in dialysis fistulae and grafts.

Why choose Mustang™ over generic balloons?

It combines controlled balloon performance, strong deliverability, and Boston Scientific quality standards trusted in vascular interventions.

Reviews

There are no reviews yet.

Be the first to review “Boston Scientific H74939171040270 Mustang OVER-THE-WIRE 5F 4.0mm x 20mm x 75cm PTA Balloon Dilatation Catheter”

Your email address will not be published. Required fields are marked *

Shopping Cart
Boston Scientific Mustang PTA balloon dilatation catheter 4.0mm x 20mm 75cm over-the-wire 5FBoston Scientific H74939171040270 Mustang OVER-THE-WIRE 5F 4.0mm x 20mm x 75cm PTA Balloon Dilatation Catheter
$499.99 Including GST
- +
Scroll to Top