The R860 XDCR Flow Sensor 1505-3231-000 is a high-precision reusable respiratory flow transducer designed for the GE CARESCAPE R860 and Engström ventilator systems.
It measures airflow within a 0–200 L/min range, enabling accurate monitoring of patient ventilation parameters in critical care environments.
Built for clinical reliability, it supports precise gas flow measurement to ensure safe and effective respiratory support.
Overview of R860 Flow Sensor 1505 3231 000
The R860 Flow Sensor 1505 3231 000 (also referred to as XDCR Flow Sensor) is a critical component used in advanced mechanical ventilation systems.
It is engineered to provide real-time, accurate measurement of inspiratory and expiratory airflow in patients connected to GE CARESCAPE R860 ventilators and compatible Engström systems.
In intensive care units (ICUs), anesthesia departments, and emergency respiratory care environments, precise airflow measurement is essential for patient safety. This sensor ensures ventilators deliver the correct tidal volume, pressure, and oxygen concentration by continuously monitoring airflow dynamics.
Its reusable design and durable construction make it a cost-effective and clinically reliable solution for hospitals and healthcare providers requiring long-term performance.
Key Features of R860 XDCR Flow Sensor
High-Precision Flow Measurement
- Measures airflow range from 0 to 200 liters per minute
- Provides accurate respiratory data for ventilator control systems
- Ensures stable performance during both low and high ventilation cycles
Compatibility with GE CARESCAPE Systems
- Specifically designed for GE CARESCAPE R860 ventilators
- Compatible with Engström ventilator platforms
- OEM-standard interface ensures seamless integration
Reusable Clinical-Grade Construction
- Designed for multiple clinical uses after proper sterilization
- Reduces hospital consumable costs
- Built from durable medical-grade materials
Reliable Respiratory Monitoring
- Supports accurate tidal volume measurement
- Enhances ventilator feedback control systems
- Helps prevent under-ventilation or over-ventilation
Easy Installation & Replacement
- Plug-and-play compatibility with ventilator sensor ports
- Lightweight and compact design
- Minimal downtime during replacement procedures
Infection Control Compliance
- Designed for cleaning and disinfection protocols
- Supports hospital infection control standards
- Reduces contamination risk in ICU environments
Benefits of Using R860 Flow Sensor 1505 3231 000
Enhanced Patient Safety
The primary advantage of this flow sensor is improved patient safety. By delivering precise airflow measurements, it helps ventilators adjust parameters accurately in real time.
Clinical Accuracy in Critical Care
ICU patients require exact respiratory support. Even small measurement deviations can affect oxygen delivery. This sensor ensures consistency in ventilation accuracy.
Cost Efficiency for Hospitals
Since the sensor is reusable, hospitals reduce recurring costs associated with disposable flow sensors. This is particularly beneficial in high-volume intensive care units.
Improved Ventilator Performance
Accurate airflow data allows ventilators like the GE CARESCAPE R860 to function optimally, improving respiratory synchronization with the patient.
Long Operational Lifespan
Built with robust engineering materials, the sensor is designed for extended usage cycles under clinical sterilization conditions.
Technical Specifications of R860 Flow Sensor
| Feature | Details |
| Product Name | R860 XDCR Flow Sensor |
| Part Number | 1505-3231-000 |
| Flow Range | 0 – 200 L/min |
| Device Compatibility | GE CARESCAPE R860, Engström Ventilators |
| Sensor Type | Respiratory Flow Transducer |
| Usage Type | Reusable (after sterilization) |
| Application | ICU, Anesthesia, Critical Care Ventilation |
| Material | Medical-grade polymer & sensor-grade components |
| Function | Airflow measurement for ventilator control |
| Installation | Direct ventilator interface connection |
| Maintenance | Cleaned and disinfected per hospital protocol |
| Accuracy Level | High-precision respiratory measurement |
How the R860 Flow Sensor Works
The R860 flow sensor (1505 3231 000) operates by measuring the flow of respiratory gases passing through the ventilator circuit. It detects changes in airflow using sensitive transduction elements that convert physical airflow into electronic signals.
These signals are transmitted to the ventilator system, which interprets them in real time to adjust:
- Tidal volume delivery
- Inspiratory pressure
- Oxygen concentration balance
- Patient-ventilator synchronization
This closed-loop feedback system ensures that patients receive optimal respiratory support based on their physiological needs.
Applications and Use Cases
Intensive Care Units (ICU)
Used in mechanically ventilated patients requiring continuous respiratory monitoring.
Emergency Medicine
Critical for emergency ventilation support in trauma and acute respiratory failure cases.
Anesthesia Ventilation Systems
Helps anesthesiologists monitor airflow during surgical procedures.
Post-Surgical Recovery
Ensures stable breathing support for patients recovering from surgery.
Long-Term Ventilation Care
Used in chronic respiratory failure management requiring ventilator assistance.
Compatibility Information
The R860 XDCR Flow Sensor 1505 3231 000 is specifically compatible with:
- GE CARESCAPE R860 Ventilator System
- Engström Carestation Ventilators
- GE Healthcare respiratory monitoring modules
Always ensure compatibility with device firmware and ventilator configuration before installation.
Installation Guidelines
Proper installation ensures accuracy and safety:
- Turn off ventilator before replacement
- Disconnect existing flow sensor carefully
- Insert new sensor into designated port
- Ensure secure locking and alignment
- Perform calibration check via ventilator system
- Resume ventilation only after confirmation of readings
Installation should be performed by trained biomedical technicians or clinical engineers.
Maintenance and Care Instructions
To ensure long-term performance:
- Clean after each clinical use
- Follow hospital-approved disinfection protocols
- Avoid exposure to excessive moisture or physical stress
- Store in sterile, dry environment
- Inspect regularly for wear or damage
Proper maintenance extends the sensor’s operational lifespan significantly.
Why Hospitals Choose R860 Flow Sensor 1505 3231 000
Hospitals prefer this sensor due to:
- Proven GE Healthcare compatibility
- Reliable ICU-grade performance
- Stable airflow measurement accuracy
- Reduced operational costs due to reusability
- Strong durability in clinical environments
It is widely used in modern respiratory care setups where precision is non-negotiable.
Frequently Asked Questions
What is the R860 Flow Sensor 1505 3231 000 used for?
It is used to measure airflow in GE CARESCAPE R860 ventilators, ensuring accurate respiratory support for patients in critical care environments.
Is the R860 XDCR Flow Sensor reusable?
Yes, this flow sensor is reusable and can be cleaned and disinfected according to hospital infection control protocols.
What is the flow range of this sensor?
The sensor measures airflow from 0 to 200 liters per minute, making it suitable for a wide range of ventilation conditions.
Which ventilators are compatible with this sensor?
It is compatible with GE CARESCAPE R860 and Engström ventilator systems.
Why is this flow sensor important in ICU care?
Because it ensures accurate measurement of respiratory airflow, which directly impacts patient safety and ventilator performance.
Can this sensor affect ventilator accuracy?
Yes, a properly functioning sensor improves ventilator accuracy by providing real-time airflow feedback for precise adjustments.
How often should the sensor be replaced?
Replacement frequency depends on usage intensity and hospital maintenance protocols, but it should be inspected regularly for calibration accuracy.
Does the sensor require calibration?
Most ventilator systems automatically calibrate the sensor upon installation, but periodic system checks are recommended.















Reviews