,

L2-9-D Linear Array Probe With XDclear Transducer Technology

You Will Receive The Following:

1 x L2-9-D Linear Array Probe with XDclear transducer technology

QTY: 1

Condition: Refurbished

EXPRESS  SHIPPING

$11,999.99 Including GST

- +
Guaranteed Safe Checkout

Medical Equipments Australia does not provide medical advice, diagnosis, or treatment. Products sold on this website are not intended to replace professional medical advice. Always consult a qualified healthcare professional regarding any medical condition or the use of medical equipment.

  • Fast Australia Wide Delivery (1 to 7 days) Depending On Location
  • No-Risk Money Back Guarantee!
  • No Hassle Refunds
  • Secure Payments
  • 24/7 Customer Support

The GE L2-9-D Linear Array Ultrasound Probe equipped with XDclear transducer technology is a high-performance diagnostic tool designed for a wide range of clinical applications. 

Known for its superior image quality and versatile functionality, the L2‑9‑D probe provides healthcare professionals with unparalleled precision and reliability in diagnostic imaging. This probe is an essential accessory for medical professionals using LOGIQ E10, LOGIQ E10s, LOGIQ Fortis, and VOLUSON E6/E8/E10 ultrasound systems.

Designed for both refurbished and original setups, the L2‑9‑D probe ensures optimal performance in imaging vascular structures, musculoskeletal components, pediatric organs, abdominal regions, and small parts. With advanced XDclear technology, this probe delivers clear, high-resolution imaging for detailed and accurate clinical assessments.

Key Features

  • Item Number / Model: 5765796
  • Equivalent Models: 5745280, H44901AI
  • Condition: Refurbished
  • Product Category: Ultrasound Probe
  • Product Family: LOGIQ E Series
  • Probe Type: Linear Array with XDclear transducer technology
  • Frequency Range: 2–9 MHz (ideal for superficial and small part imaging)
  • Clinical Applications: Musculoskeletal, Vascular, Pediatric, Abdominal, Small Parts

Advanced XDclear Transducer Technology

The XDclear technology integrated into the L2‑9‑D probe enhances signal-to-noise ratio and improves tissue penetration, enabling precise visualization of both superficial and deep structures. This technology ensures:

  • High-Resolution Imaging: Delivers sharper, clearer images with exceptional contrast.
  • Improved Diagnostic Confidence: Enables accurate assessments of complex anatomical structures.
  • Optimized Tissue Differentiation: Helps differentiate between soft tissues, muscles, vessels, and small organs.

The XDclear linear array is engineered to maximize clinical workflow efficiency and diagnostic accuracy, making it a preferred choice for hospitals, clinics, and specialized imaging centers.

Compatibility and System Integration

The L2‑9‑D Linear Probe is fully compatible with multiple GE Healthcare ultrasound systems:

  • LOGIQ E10
  • LOGIQ E10s
  • LOGIQ Fortis
  • VOLUSON E6/E8/E10

Note: Compatibility may vary depending on system software version. Always refer to the user manual or system documentation before installation to ensure full integration.

Clinical Applications

1. Musculoskeletal Imaging

The L2‑9‑D probe is highly effective in imaging muscle structures, tendons, ligaments, and joints. Its high-frequency linear array allows for:

  • Accurate detection of muscle tears, inflammation, and soft tissue injuries
  • High-resolution visualization of tendons and ligament attachments
  • Enhanced precision in guided injections or musculoskeletal interventions

2. Vascular Studies

For vascular diagnostics, this probe excels in providing:

  • Clear imaging of arteries and veins, including carotid, peripheral, and deep veins
  • Assessment of vascular stenosis, occlusions, and blood flow patterns
  • Optimized Doppler performance for hemodynamic studies

3. Pediatric Ultrasound

The L2‑9‑D probe is ideal for pediatric imaging due to:

  • Its high-resolution linear array, suitable for small anatomy
  • Enhanced imaging of organs such as kidneys, liver, and thyroid
  • Reduced scanning time while maintaining superior image clarity

4. Abdominal Imaging

With XDclear technology, the L2‑9‑D provides:

  • Detailed visualization of abdominal organs, including liver, pancreas, kidneys, and gallbladder
  • Precise detection of lesions, cysts, and small anatomical abnormalities
  • Improved penetration for larger patients while maintaining resolution

5. Small Parts Imaging

The probe is optimized for superficial small parts such as:

  • Thyroid, breast, and lymph nodes
  • Nerve bundles and peripheral soft tissues
  • Small musculoskeletal structures for precise clinical interventions

Why Choose the L2‑9‑D Linear Array Probe

Enhanced Diagnostic Accuracy

Thanks to XDclear transducer technology, clinicians can achieve high-definition imaging for detailed diagnostic evaluation, improving clinical outcomes.

Reliable Refurbished Option

This probe is available as a refurbished unit, thoroughly tested to meet OEM performance standards, providing a cost-effective alternative without compromising quality.

Multi-Compatibility

Seamlessly integrates with various GE ultrasound systems, ensuring flexibility in clinical settings.

User-Friendly Design

  • Lightweight and ergonomic design for easy handling and extended scanning sessions
  • Durable construction ensures long-term reliability

Technical Specifications

FeatureSpecification
Probe TypeLinear Array
TechnologyXDclear Transducer
Frequency Range2–9 MHz
Imaging DepthSuperficial to mid-depth (up to 9 cm)
Clinical ApplicationsMusculoskeletal, Vascular, Pediatric, Abdominal, Small Parts
Compatible SystemsLOGIQ E10, E10s, Fortis, VOLUSON E6/E8/E10
ConditionRefurbished
Item Number5765796
Equivalent Items5745280, H44901AI

Benefits

  1. High-Resolution Imaging: Capture every detail for accurate diagnosis.
  2. Wide Clinical Application: One probe for musculoskeletal, vascular, pediatric, abdominal, and small parts imaging.
  3. Enhanced Workflow Efficiency: XDclear technology ensures faster, more precise scanning.
  4. Durable and Reliable: Designed for extended clinical use without compromising performance.
  5. Cost-Effective Refurbished Option: OEM standards tested, saving cost for healthcare facilities.

Installation and Maintenance Tips

  • Always refer to the GE ultrasound system user manual before installation.
  • Avoid dropping or striking the probe; it contains sensitive electronics.
  • Clean with approved disinfectants compatible with ultrasound probes.
  • Check connector pins regularly for wear and debris.

Frequently Asked Questions

What systems is the L2‑9‑D probe compatible with?

The L2‑9‑D probe works with LOGIQ E10, LOGIQ E10s, LOGIQ Fortis, and VOLUSON E6/E8/E10 ultrasound systems. Compatibility may vary with software versions, so always consult the system manual.

What clinical applications is this probe suitable for?

This linear array probe is ideal for musculoskeletal, vascular, pediatric, abdominal, and small parts imaging. It is particularly useful for detecting small anatomical abnormalities and soft tissue injuries.

Is the probe new or refurbished?

This product is a refurbished unit, thoroughly tested to meet GE OEM performance standards, offering high-quality imaging at a cost-effective price.

What is the frequency range of the L2‑9‑D probe?

The probe operates at 2–9 MHz, making it suitable for both superficial and moderately deep tissue imaging.

Can I use this probe for pediatric imaging?

Yes, the L2‑9‑D linear probe is optimized for pediatric imaging, offering clear visualization of small organs and soft tissues.

What makes XDclear technology important?

XDclear enhances the signal-to-noise ratio, improves tissue penetration, and provides high-resolution images for accurate diagnostic decisions.

Are there equivalent part numbers for the L2‑9‑D probe?

Yes, equivalent items include 5745280 and H44901AI, compatible with the same systems.

How should I clean and maintain the probe?

Use manufacturer-approved disinfectants, avoid physical impact, and check connectors regularly. Proper care ensures longevity and consistent image quality.

Can this probe detect vascular occlusions?

Yes, it is ideal for vascular studies, including detection of stenosis, occlusions, and blood flow patterns with Doppler imaging.

Is this probe suitable for small part imaging like thyroid or breast?

Absolutely, its high-frequency linear array provides detailed imaging of superficial small parts, including thyroid, breast, lymph nodes, and peripheral nerves.

Reviews

There are no reviews yet.

Be the first to review “L2-9-D Linear Array Probe With XDclear Transducer Technology”

Your email address will not be published. Required fields are marked *

Shopping Cart
GE L2-9-D Linear Array Ultrasound Probe front view with XDclear technology for LOGIQ E10 systemsL2-9-D Linear Array Probe With XDclear Transducer Technology
$11,999.99 Including GST
- +
Scroll to Top