SpO2 Adapter Cable 3.0m for Masimo RD Sensors (4108)
This 3.0m reusable SpO2 Adapter Cable connects Masimo RD SpO2 sensors to Masimo Rainbow SET patient monitors and pulse oximeters, extending the reach between the patient and the monitor. Reference part number: Masimo 4108.
The longer cable length gives extra reach between the patient and the monitor, which suits bedside care, emergency departments and transport monitoring.
Specifications
| Part Number | SA-008RB-30RD |
| Reference Part Numbers | Masimo 4108, RD SET MD14-08 |
| Sensor Technology | Masimo RD |
| Connects To | Masimo Rainbow SET monitors |
| Cable Length | 3.0m |
| Use | Reusable |
| Condition | New |
| Packaging | 1 pcs/bag |
Works With These Monitors
- Mindray: Duo with Masimo Option, Trio with Masimo Option, Passport 2 with Masimo Option, Passport V with Masimo Option, Spectrum with Masimo Option, Spectrum OR with Masimo Option, V12 with Masimo Option, V21 with Masimo Option, Accutorr V, Duo, Passport 2, Passport V, Spectrum, Spectrum OR, Trio
- Masimo: Rad 5, Rad 5v, Rad 9, Radical, Bitmos Sat 801, Bitmos 901 M, Bitmos 901 ML, Rad-8, Pronto 7, Rad 57, Rad 87, Radical-7
- Datascope: Passport 2 with Masimo Rainbow Option, Passport 2LT with Masimo Rainbow Option, Passport XG with Masimo Rainbow Option, Accutorr Plus with Masimo Rainbow Option, Accutorr Plus, Passport 2LT, V12, V21, T8, Accutor V, EPM4, Passport XG
- GE Healthcare: Dinamap ProCare with Masimo Pro 1000, ProCare 300, ProSeries V2, V300, ProCare Ausculatory 400, Pro 300V2
- Physio-Control: Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E
- Welch Allyn: 45NE0-E1 LX, Spot Vital Signs 42MTB-E1, Propaq CS, Spot Vital Signs LXi, 53STP
- Bitmos: sat 800, sat 801, sat 805, sat 816, satPuls
- Zoll: E Series, M Series, R Series
- Invivo: Escort II OPT30 Prism
- Venni: All
- Atom: V-2100G
- Respironics: Alice 5
- Comen: C60
Before ordering, check your monitor model against this list and confirm that your sensors use Masimo RD technology.
Frequently Asked Questions
What does this SpO2 adapter cable do?
It connects Masimo RD SpO2 sensors to Masimo Rainbow SET monitors and extends the reach between the patient and the monitor.
How do I confirm it fits my monitor?
Check your monitor brand and model against the model list above and compare the reference part number 4108 with the cable you are replacing. If you are unsure, send us your monitor model and we will confirm the fit before you order.
Is the cable reusable?
Yes. It is a reusable cable and can be cleaned between patients according to your facility’s procedures.





![SpO2 Adapter Cable 3.0m for Nellcor Oxismart Sensors [SA-002-30]](https://medicalequipmentsaustralia.com.au/wp-content/uploads/2026/10/spo2-adapter-cable-3-0m-for-nellcor-oxismart-sensors-sa-002-30-mea-300x300.webp)






Reviews
There are no reviews yet.