The BCI Forehead SpO2 Sensor is a new, reusable pulse oximetry sensor with a 1.0m cable and 9-pin connector that measures oxygen saturation (SpO2) and pulse rate from the patient’s forehead. It suits all patient sizes, is supplied with a headband, and is built to the BCI 9-pin SpO2 reference specifications for BCI / Smiths Medical pulse oximeters and patient monitors.
Key Benefits of the BCI Forehead Pulse Oximeter Sensor
- Alternative monitoring site: Forehead placement is useful when fingers or ears are unavailable, injured or hard to access.
- One sensor for all patient sizes: A single flat sensor head covers adult, pediatric and smaller patients, reducing the stock you need to hold.
- Reusable design: Cleanable between patients for a lower cost per use than single-use sensors.
- Secure fit: The supplied headband holds the sensor flat against the forehead during monitoring.
- Peace of mind: Brand-new unit backed by a 12-month warranty.
Features of the Reusable Forehead SpO2 Sensor
- Flat, low-profile forehead sensor head
- 1.0m (3.3 ft) grey sensor cable
- 9-pin D-style connector for BCI 9-pin SpO2 inputs
- Soft headband included
- CE marked (as printed on the cable label)
- Packed 1 set per bag
Technical Specifications
| Specification | Detail |
|---|---|
| Product | BCI All Sizes Forehead SpO2 Sensor |
| Part Number / SKU | BCI-ALLSIZE-FH-SPO2-9PIN-1M |
| Monitor Brand | BCI / Smiths Medical |
| Sensor Type | Forehead |
| Patient Size | All Sizes |
| Cable Length | 1.0m (3.3 ft) |
| Connector | 9-pin |
| Lifecycle | Reusable |
| Condition | New |
| Unit | 1 set per bag (sensor with headband) |
| Warranty | 12 Months |
Works With These Monitors and Pulse Oximeters
This forehead oxygen saturation sensor works with the following equipment that uses the BCI 9-pin SpO2 connection. Always confirm your monitor’s connector before ordering.
| Brand | Models |
|---|---|
| BCI | 1301, 1302, 1303, 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3304 (Autocorr), 3400, 3401, 3402 (MiniCorr), 3403, 3404, 3404 (Autocorr Plus), 3444, 6100, 8400 (Capnocheck II), 8401 (Capnocheck II), 9004 (Capnocheck Plus), 9100, 9200, 9200 (Advisor), Advisor, Autocorr, Capnocheck 9004, Mini Torr, Mini Torr Plus, Spectro 10, Spectro 20, SPECTRO2, SPECTRO2 10, SPECTRO2 20, SPECTRO2 30, SurgiVet, Vet/Ox Plus 4600 |
| Smiths Medical | SurgiVet V3304 |
| Armstrong | AD-900, AD-1000, AD-2000, AD-3000, AD-4000 |
| Artema S&W | Diascope |
| ChoiceMMed | HCSMD400, MD300A, MD300I, MD300K1, MD300M, MMED6000DP-M3, MMED6000DP-M7, MMED6000DP-S6, MMED6000DP-SF |
| CMOS Drake | All models with 9-pin connectors |
| Datex Ohmeda | 4700 |
| Digicare | Digimax 2000, Digimax 5500 |
| Draeger | Oxipac 2000, Oxipac 2500 |
| Envitec | PulsiQuant 8040 |
| Goldway | UT4000A |
| Infinium | Oxcyon II |
| Invacare | 3300nv |
| Larsen & Toubro | Cosmic, Galaxy, Planet, Planet 50, Star 50, Star 55, Stellar P |
| Mennen Medical | 1300 |
| RGB | Omicrom FT, Omicron Premium |
| Spacelabs | PRO2 |
| Venni | VI-100A, VI-200A |
| Weinmann | Oxycount Mini |
Use Cases
- Hospitals, clinics and day-surgery units running BCI pulse oximeters
- Patients whose fingers are not a practical measurement site
- Biomedical engineering departments replacing worn or damaged sensors
- Facilities wanting one reusable sensor that covers every patient size
Application and Care
How to apply
- Clean and dry the forehead skin before placement.
- Position the sensor flat on the forehead and secure it with the headband, firm but not tight.
- Connect the 9-pin plug to the monitor and confirm a stable reading.
Cleaning
- Disconnect the sensor before cleaning and wipe it according to your facility’s protocol and the monitor manufacturer’s guidance.
- Do not immerse or autoclave the sensor, and check the cable for damage before each use.
Frequently Asked Questions
What is the BCI Forehead SpO2 Sensor used for?
It measures blood oxygen saturation and pulse rate from the forehead when connected to a BCI 9-pin pulse oximeter or patient monitor.
Which patients can use this forehead sensor?
It is an all-sizes sensor, so the same unit can be used across patient size groups.
Is this sensor reusable?
Yes. It is a reusable sensor that can be cleaned between patients.
How long is the cable and what connector does it have?
The cable is 1.0m (3.3 ft) long and ends in a 9-pin connector.
Is a headband included?
Yes. Each set is supplied with a headband to hold the sensor in place.
What warranty is provided?
The sensor is new and covered by a 12-month warranty.